Message was not transmitted (14)<br />

The last transmit request was not executed by the CAN controller. This may be<br />

due to the error status of the controller, or due to the accumulation of too many<br />

higher priority messages.<br />

DLC error (1128, 111, 112)<br />

With the CANIB card a smaller DLC is specified in the DPRAM setup than<br />

should be transmitted. This size must be adjusted in the CAPL generator block<br />

or replay block.<br />

This error can trigger other consequential errors. When problems are encountered<br />

the computer should be rebooted with a cold start!<br />

Due to a firmware error in CANIB, a DLC equal to 0 cannot be processed.<br />

Therefore, it is set to at least 1 in the driver. However, an adjustment for calculating<br />

the size of the available DPRAM will not be implemented until Version 2.0.<br />

DPRAM Overflow (5) DPRAM<br />

In the message setup more messages are defined than the DPRAM can receive.<br />

Due to the fact that <strong>CANoe</strong> checks the number of messages, this report<br />

doesn't appear.<br />

Incorrect controller no. (3,10,113)<br />

An attempt was made to access a nonexistent CAN controller. Most CAN cards<br />

supported by <strong>CANoe</strong> have two controllers. But there are also cards with just<br />

one controller.<br />

Remedy: Look for a message CANn... in the CAPL programs, where n is<br />

greater than the number of existing controllers. This must be replaced by a correct<br />

number.<br />

Incorrect module number (109)<br />

No CANIB was found at the address given. If the port address has been<br />

jumpered over on the card, this must be communicated to <strong>CANoe</strong> See the<br />

manual.<br />

Incorrect checksum (1368)<br />

The CAN controller detected a faulty CRC checksum.<br />

Incorrect terminating code (1432)<br />

For CANIB cards this is the error code for general firmware problems. These<br />

occur primarily in BUSOFF and ERROR_PASSIVE states.<br />

Incorrect card type (8)<br />

<strong>CANoe</strong> card driver and hardware are not compatible.<br />

© Vector Informatik GmbH <strong>CANoe</strong>/<strong>DENoe</strong> Manual Version 4.1.1<br />