42<br />

are interpreted as gateway definitions. To meet this rule, there must be a CAPL<br />

block in the simulation setup that has to be assigned to a database node and<br />

has to be included as a gateway.<br />

It does not meet this rule, when a CAPL block is included as a node in one of<br />

the buses while no database is assigned to this bus.<br />

• 3rd Rule: All gateways that are defined in the databases must be included<br />

as gateways in the assigned buses within the simulation setup.<br />

Example:<br />

This rule is slightly different to the 2nd rule. It does not meet to include a gateway<br />

– that is defined in the databases – in the available buses of the simulation<br />

setup. The concerned CAPL block must be included as a gateway in the buses<br />

to which the databases are assigned to.<br />

2.2 Measurement/Measurement Setup<br />

2.2.1 Measurement Start<br />

The measurement is started by pressing the F9 key, by choosing Start│Start in the<br />

main menu or by activating the start button on the toolbar. In Online mode data<br />

can now be received and evaluated from the bus or can be sent out onto the bus.<br />

The data flow diagram shows you which analysis and transmit blocks are active during<br />

the particular measurement.<br />

At the start of an Online measurement, first the CAN board is initialized. If this cannot<br />

be done, an error message is output and the measurement is terminated.<br />

During the measurement the user can configure the Trace block, Data block and the<br />

scaling of the Statistics window and Data window. However, the menu items in the<br />

popup menus of the remaining blocks are masked out for the duration of a measurement.<br />

You cannot parameterize these blocks until after the measurement run has<br />

ended. All keyboard inputs during the measurement are passed through directly to<br />

the function blocks (CAPL programs, generator block, etc.). They are shown in the<br />

relevant status window on the toolbar. The only available program controls are the<br />

key (terminate measurement) and all of the key combinations with the <br />

key (Window control under Windows).<br />

You can stop the measurement by pressing the key, selecting the main menu<br />

item Start│Stop or activating the button on the toolbar.<br />

Internally, the measurement can be terminated by the elapse of the post-trigger time<br />

after triggering has occurred, or by the call of the stop() function from a CAPL program.<br />

Note: During high system loading the stopping process may take a certain<br />

amount of time, since the system's message buffer must be emptied. A repeated<br />

stop command (double click) causes the buffered data to be ignored,<br />

and the measurement is terminated immediately, even under high<br />

system loading.<br />

© Vector Informatik GmbH <strong>CANoe</strong>/<strong>DENoe</strong> Manual Version 4.1.1