are interpreted as gateway definitions. To meet this rule, there must be a CAPL<br />
block in the simulation setup that has to be assigned to a database node and<br />
has to be included as a gateway.<br />
It does not meet this rule, when a CAPL block is included as a node in one of<br />
the buses while no database is assigned to this bus.<br />
• 3rd Rule: All gateways that are defined in the databases must be included<br />
as gateways in the assigned buses within the simulation setup.<br />
Example:<br />
This rule is slightly different to the 2nd rule. It does not meet to include a gateway<br />
– that is defined in the databases – in the available buses of the simulation<br />
setup. The concerned CAPL block must be included as a gateway in the buses<br />
to which the databases are assigned to.<br />
2.2 Measurement/Measurement Setup<br />
2.2.1 Measurement Start<br />
The measurement is started by pressing the F9 key, by choosing Start│Start in the<br />
main menu or by activating the start button on the toolbar. In Online mode data<br />
can now be received and evaluated from the bus or can be sent out onto the bus.<br />
The data flow diagram shows you which analysis and transmit blocks are active during<br />
the particular measurement.<br />
At the start of an Online measurement, first the CAN board is initialized. If this cannot<br />
be done, an error message is output and the measurement is terminated.<br />
During the measurement the user can configure the Trace block, Data block and the<br />
scaling of the Statistics window and Data window. However, the menu items in the<br />
popup menus of the remaining blocks are masked out for the duration of a measurement.<br />
You cannot parameterize these blocks until after the measurement run has<br />
ended. All keyboard inputs during the measurement are passed through directly to<br />
the function blocks (CAPL programs, generator block, etc.). They are shown in the<br />
relevant status window on the toolbar. The only available program controls are the<br />
key (terminate measurement) and all of the key combinations with the <br />
key (Window control under Windows).<br />
You can stop the measurement by pressing the key, selecting the main menu<br />
item Start│Stop or activating the button on the toolbar.<br />
Internally, the measurement can be terminated by the elapse of the post-trigger time<br />
after triggering has occurred, or by the call of the stop() function from a CAPL program.<br />
Note: During high system loading the stopping process may take a certain<br />
amount of time, since the system's message buffer must be emptied. A repeated<br />
stop command (double click) causes the buffered data to be ignored,<br />
and the measurement is terminated immediately, even under high<br />
system loading.<br />
© Vector Informatik GmbH <strong>CANoe</strong>/<strong>DENoe</strong> Manual Version 4.1.1