9.14.8 Weird Spurious Events from MOST bus<br />

187<br />

In some rare cases there might be some spurious events from the MOST bus. This<br />

may include invalid timestamps or even random data. There are some plausibility<br />

checks performed on the timestamps which should detect these events. In order to<br />

avoid an impairment of the time synchronization the timestamps of these events will<br />

be set to the recent simulation time of <strong>CANoe</strong>. The events will be shown in the trace<br />

window and logging file and will be reported in the write window as ‘weird time<br />

stamp’.<br />

This problem seems to be provoked by a high overall load (CAN and MOST) or a<br />

slow PC. Please try to reduce the load by<br />

• Disabling unused analysis functions of <strong>CANoe</strong><br />

• using HW filtering of the Optolyzer in spy mode<br />

• activating acceptance masks in the CAN chip setup<br />

• using a faster PC<br />

This problem is difficult to reproduce and seems to be related with the ActiveX control.<br />

It will be investigated further and solved as soon as possible.<br />

9.14.9 Transmit Acknowledgement<br />

When using older versions of the Optolyzer ActiveX Control (versions before 2.1.1),<br />

transmit acknowledgements for the transmission of a MOST control frame do not<br />

have a hardware generated timestamp. So the ‘origtimestamp’ is set to zero and the<br />

synchronized timestamp is set to an estimated value depending on the time of reception<br />

of the acknowledgement.<br />

These timestamps are shown with a trailing ‘?’ in the trace window to indicate that<br />

these events are not exactly in chronological order with the other events.<br />

9.14.10 Timestamps of CAN and MOST constantly drift apart<br />

Time synchronization only works with CAN driver versions from 3.4 and later. Please<br />

install the drivers enclosed in this distribution, or visit our web site at<br />

http://www.vector-informatik.de to download the drivers.<br />

Ensure that the check box ‘Synchronize Hardware’ is enabled in the Global Settings<br />

tab of the CAN Driver Configuration dialog.<br />

9.14.11 Measurement stops after configuration of trace window<br />

In some cases the measurement will be stopped immediately if the configuration dialog<br />

of a trace window is opened during measurement. This problem can be traced<br />

back to an improper installation of the ActiveX control OptoControl.<br />

Please try to reinstall the OptoControl. First deinstall OptoControl using Windows<br />

(Settings, Control Panel, Add/Remove Software). Ensure that there are no entries<br />

belonging to the OptoControl left in the registry (search for "*opto*"). Than install OptoControl<br />

again. Use the version provided on the <strong>CANoe</strong> CD according to the used<br />

operating system (on the CD under Drivers\Optolyzer\OptoControl).<br />