112<br />
Figure 64: Data Window Configuration<br />
All signals of the signal list are shown in the list box at the upper left of the dialog.<br />
Here you can accept new signals from the associated database. When copying, the<br />
abbreviated signal name is modified such that no ambiguities result. The abbreviated<br />
name appears during the measurement as the signal identifier in addition to the actual<br />
signal value.<br />
With the [Define] and [Edit] buttons you can enter a new signal description - independent<br />
of the database - in the Data window or modify an existing signal description.<br />
3.6.2 Display Types<br />
Signal values can be displayed in the Data window in the modes shown below. The<br />
output width of the signal value is automatically calculated from the bit length and<br />
conversion formula. <strong>CANoe</strong> takes the necessary signal data from the database:<br />
Physical<br />
The raw data are extracted from the CAN message, scaled by the (linear) conversion<br />
formula, and displayed as decimal fixed point numbers.<br />
Example: Signal T consists of 5 bits, is unsigned, has a factor of 10 and an offset<br />
of 0. Then the possible raw value range is 0-31, and the physical value<br />
range is 0-310. Therefore, the necessary output width is 3 characters.<br />
© Vector Informatik GmbH <strong>CANoe</strong>/<strong>DENoe</strong> Manual Version 4.1.1