09.01.2013 Views

CANoe DENoe - KEMT FEI TUKE

CANoe DENoe - KEMT FEI TUKE

CANoe DENoe - KEMT FEI TUKE

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

For example, the entire measurement can be recorded in Toggle Trigger mode by<br />

selecting Start and Stop as the trigger conditions. In this case, a start-of-block trigger<br />

is activated at the start of measurement, and the measurement is logged until the<br />

end-of-block trigger occurs when the measurement is stopped. Pre-trigger and posttrigger<br />

times are ignored when this option is set.<br />

You can determine whether the trigger action should be executed once or multiple<br />

times. If the option Measurement stop after n triggers is selected in the trigger's<br />

configuration dialog, the measurement process is stopped after the post-trigger time<br />

of the nth trigger has elapsed.<br />

2.7.1.2 Trigger Events<br />

You can define trigger events using the five check boxes in the configuration dialog.<br />

The following types are available to you:<br />

The following types are available:<br />

• Trigger on Start. Triggering occurs unconditionally and immediately at the start<br />

of measurement. The logging time period is defined exclusively by the posttrigger<br />

time in this case.<br />

• Trigger on Stop. Triggering is executed at the end of the measurement. Triggering<br />

can be activated by the CAPL function stop() or by the key. The<br />

logging time period is defined exclusively by the pre-trigger time in this case.<br />

• Trigger by a CAPL program: Using CAPL programming methods arbitrarily<br />

complex conditions can be formulated, which can depend on the occurrence of<br />

various events. Triggering is activated when the intrinsic function trigger() is<br />

called by a procedure. The configured pretrigger and post-trigger times define<br />

the logging time period for this trigger.<br />

• Trigger when certain messages occur. With the Event trigger type, triggering<br />

occurs when specific messages with specific attributes occur. To define these<br />

attributes press the [Condition] button. The configured pretrigger and posttrigger<br />

times define the logging time period for this trigger.<br />

• Trigger on Error frames. Triggering is executed whenever an error frame occurs.<br />

The configured pretrigger and post-trigger times define the logging time<br />

period for this trigger.<br />

2.7.1.3 Time window<br />

In the configuration dialog you also define the time window (the pre-trigger and posttrigger<br />

times in milliseconds) around each trigger.<br />

The pre-trigger time defines the time interval before activation of the trigger condition<br />

which is to be saved. If the trigger condition occurs so early that the pre-trigger time<br />

is greater than the time since the start of the measurement, only those data occurring<br />

prior to the trigger can be saved. Valid pre-trigger times must lie in the range of 0 to<br />

180000 ms.<br />

© Vector Informatik GmbH <strong>CANoe</strong>/<strong>DENoe</strong> Manual Version 4.1.1<br />

63

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!