92<br />
If you work without a real bus and real controllers, you can operate <strong>CANoe</strong> in pure<br />
simulation mode. Switch the operating mode in the simulation dialog (Menu item<br />
Configuration│Simulation...) from Real Bus to Simulated Bus. Bus access (sending<br />
and receiving messages) is then simulated.<br />
In simulation mode an animation factor can be specified. The (simulated) measurement<br />
then appears slowed by this factor. Accordingly, the simulation is accelerated<br />
for simulation factors between zero and one. (For example, if you specify the<br />
value 0.1, the measurement would be accelerated by a factor of 10.)<br />
The supplemental icons and appearing on the toolbar can be used to resume<br />
the simulation for a defined period of time or to stop a running simulation at any point<br />
in time. The length of the time step is set in the input box to the right of the icons; input<br />
is in milliseconds.<br />
Slave mode is a special simulation mode in which the time sequencing of the measurement<br />
(time base) is controlled by an external program. A typical usage would be to<br />
control the measurement by a master program which accesses the <strong>CANoe</strong> simulation<br />
object via the COM.<br />
CAPL Debugging enables the display of variables of CAPL nodes during a <strong>CANoe</strong><br />
simulation as well as stopping simulations by the use of CAPL commands.<br />
This dialog allows settings for:<br />
• Activating/deactivating the execution of the halt CAPL command.<br />
(default: activated)<br />
The execution of all halt commands within a <strong>CANoe</strong> configuration can be enabled/disabled.<br />
• Activating/deactivating the display of the full path in the call stack<br />
(default: deactivated)<br />
You can select whether the call stack shows only the name of the CAPL node<br />
or the full path.<br />
• Activating/deactivating the execution of the inspect CAPL command<br />
(default: activated)<br />
The execution of all inspect commands within a <strong>CANoe</strong> configuration can be<br />
enabled/disabled.<br />
© Vector Informatik GmbH <strong>CANoe</strong>/<strong>DENoe</strong> Manual Version 4.1.1