120<br />

4 Blocks and Filter<br />

In the measurement setup there are square points (hotspots) between the basic function<br />

blocks, at which additional function blocks can be inserted or the data flow can<br />

be blocked. The hotspots themselves allow all data to pass unhindered.<br />

When a hotspot is clicked on with the right mouse button (or selected with the cursor<br />

keys and then activated with ), a popup menu appears with the following menu<br />

commands:<br />

If one of the first seven menu commands is clicked on, a block is inserted in the data<br />

flow plan which satisfies the particular function. New hotspots appear before and after<br />

this block, so that additional blocks can be inserted. The last menu item is a special<br />

case. If it is activated a broken hotspot appears, which is intended to show that the<br />

flow of information is blocked at this point.<br />

Function blocks can be recognized by their appearance or by their labels in the data<br />

flow chart. A P stands for a CAPL node (Program block), PF and SF designate the<br />

Pass and Stop Filters, PE and SE are the corresponding filters for environment variables,<br />

a G refers to a Generator block, an IG to the Interactive Generator block and R<br />

stands for a Replay block. The channel filter is represented with a special icon.<br />

All blocks have popup menus which the user can open by either clicking with the right<br />

mouse button or by selecting the block in the data flow plan and then pressing <br />

. The first menu item opens a configuration dialog for the particular block, which only<br />

serves to parameterize the block (there are two configuration dialogs for the generator<br />

block, which can be opened by the first two menu items). By selecting the last<br />

item in the popup menu Delete this node, you can remove the block from the data<br />

flow plan. All configuration information is lost in the process. However, the CAPL<br />

source files of the CAPL node and the log file of the replay block are not deleted.<br />

From the popup menu you can assign a comment to each function block and analysis<br />

block. The comment is displayed by default. With the function Show comment in the<br />

popup menu you can enable and disable the display separately for each block.<br />

Please note that the size of the displayed comment depends on the actual position of<br />

the function block and the space available for the display. Independent of this, it is<br />

always the case that only the first two lines of the comments are displayed. It is advisable<br />

to use only short key words in the first two lines and to enter more elaborate<br />

information further below in the text.<br />

© Vector Informatik GmbH <strong>CANoe</strong>/<strong>DENoe</strong> Manual Version 4.1.1