09.01.2013 Views

CANoe DENoe - KEMT FEI TUKE

CANoe DENoe - KEMT FEI TUKE

CANoe DENoe - KEMT FEI TUKE

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

9.13.3 MOST XML Catalog<br />

185<br />

The demo replays a logging file in offline mode to show the disassembly capabilities<br />

of the Trace window. Therefore the configuration imports two sample XML Function<br />

Catalogs. No real hardware is required for running the demo.<br />

9.14 Known Problems & Trouble Shooting<br />

9.14.1 Measurement Windows frequently disabled<br />

In spite of a moderate bus load on the used CAN or MOST channels, the measurement<br />

windows frequently show a notification ‘disabled’ in the title bars.<br />

Please check:<br />

• Are the COM port settings in the windows control panel correct?<br />

They must be 115.2 kBaud, 8 Bit, no parity, 1 Stop Bit, Hardware flow control<br />

9.14.2 <strong>CANoe</strong> doesn’t receive any MOST Frames<br />

Please check at first:<br />

• Does the Optolyzer have light&lock<br />

• Are there MOST frames to receive<br />

• Is the Optolyzer addressed (either in Spy Mode, or with correct node or group<br />

address)<br />

The mode is configured either in the MOST hardware configuration dialog or in<br />

a CAPL program.<br />

• In spy mode: Is the HW Filter switched off?<br />

• Is there a message ‘MOST x: Obsolete Firmware? (Version >2.41c required)’ in<br />

the write window?<br />

This indicates that the time synchronization couldn’t startup. An obsolete firmware<br />

version of the Optolyzer box may be the reason.<br />

If sending MOST frames and receiving Tx acknowledgements works well, but still no<br />

MOST frames are received, the firmware of the Optolyzer box may be obsolete. For<br />

usage of <strong>CANoe</strong> .MOST at least version 2.50 of the firmware is needed.<br />

9.14.3 <strong>CANoe</strong> doesn’t receive some MOST Frames<br />

When running an Optolyzer box in node mode (Master, Slave), only messages sent<br />

to the node’s address will be received. Furthermore, acknowledged frames will be<br />

processed, only. Not acknowledged frames can solely be detected in Spy mode.<br />

While driving the Optolyzer box with high load (simultaneous transmission and reception<br />

of multiple messages), the receiver (Optolyzer) may need several send retries<br />

before it acknowledges a reception to the sender. Adjust the number of retries at<br />

sender site.<br />

© Vector Informatik GmbH <strong>CANoe</strong>/<strong>DENoe</strong> Manual Version 4.1.1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!