- Page 1 and 2:
CANoe DENoe .CAN.LIN.MOST.FlexRay M
- Page 3 and 4:
IV International Quality Standard C
- Page 5 and 6:
VI Contents 1 Introduction.........
- Page 7 and 8:
VIII 2.7.4.2 Configuration of Onlin
- Page 9 and 10:
X 4.2.1.6 Entering Mode-Dependent S
- Page 11 and 12:
XII 9.4 Synchronized timestamp ....
- Page 14 and 15:
1 Introduction In this chapter, you
- Page 16 and 17:
The control panels provide a user-f
- Page 18 and 19:
Control box/Check box Comment box B
- Page 20 and 21:
figuration dialog for the active bl
- Page 22 and 23:
Make sure that you begin this tour
- Page 24 and 25:
After then select + and Setup from
- Page 26 and 27:
generator block, whereby the first
- Page 28 and 29:
Figure 17: Transmit List for Genera
- Page 30 and 31:
Figure 20: Statistics Report Beside
- Page 32 and 33:
must be subtracted from the result.
- Page 34 and 35:
Figure 25: Data Window With the hel
- Page 36 and 37:
figuration from the data source. Yo
- Page 38 and 39:
Unit 7: Create a CAPL program with
- Page 40 and 41:
1.3.12 Simulation of Distributed Sy
- Page 42 and 43:
In the configuration under consider
- Page 44 and 45:
} msg.bsSwitch = getValue(this); //
- Page 46 and 47: The panels are generated as display
- Page 48 and 49: 1.6 Particularities of the Demo Ver
- Page 50 and 51: Figure 34: CANoe during a measureme
- Page 52 and 53: Main menu line Toolbar Data window
- Page 54 and 55: The information exchange between th
- Page 56 and 57: 2.2.2 Working with Configurations A
- Page 58 and 59: Figure 38: Dialog for configuring r
- Page 60 and 61: Figure 40: Message and Signal Explo
- Page 62 and 63: The search sequence in the database
- Page 64 and 65: • The channel configuration does
- Page 66 and 67: Normal Oper. Load Oper. Overload Fi
- Page 68 and 69: To filter out certain messages from
- Page 70 and 71: Panels to be Opened at Measurement
- Page 72 and 73: Furthermore, the panel configuratio
- Page 74 and 75: In the Entire Measurement trigger m
- Page 76 and 77: For example, the entire measurement
- Page 78 and 79: If a data loss occurs in spite of t
- Page 80 and 81: Event type Format in ASCII Logging
- Page 82 and 83: Nevertheless, it is often the case
- Page 84 and 85: Number format: Binary A mask is ent
- Page 86 and 87: 2.8 COM-Server A COM-Server is impl
- Page 88 and 89: Message was not transmitted (14) Th
- Page 90 and 91: Command from driver not supported (
- Page 92 and 93: supplied with the card. Operation o
- Page 94 and 95: The CAN controllers are provided wi
- Page 98 and 99: 3 Windows You can modify the arrang
- Page 100 and 101: 3.1.2 Layout of the Simulation Setu
- Page 102 and 103: You configure the measurement setup
- Page 104 and 105: time stamp 2.7000 sec CANoe transm
- Page 106 and 107: Figure 55: Simulation Dialog Note:
- Page 108 and 109: WU = Wake up or TE = Transceiver er
- Page 110 and 111: fixed position, cyclic update outpu
- Page 112 and 113: 3.3.3 Trace Window Options from the
- Page 114 and 115: 3.4.1 Selecting Signals 101 In the
- Page 116 and 117: 103 For all signals you have entere
- Page 118 and 119: 105 Note: It is always the case tha
- Page 120 and 121: 107 10x , n = [1 to 9], x = whole n
- Page 122 and 123: 109 To optimize the Graphics window
- Page 124 and 125: The popup menu command Copy content
- Page 126 and 127: Display type: Decimal The raw data
- Page 128 and 129: ing. However, to obtain reasonable
- Page 130 and 131: Figure 67: Statistical evaluation o
- Page 132 and 133: Figure 69: Bus Statistics Window 11
- Page 134 and 135: If you have not entered any comment
- Page 136 and 137: Figure 71: Generator block Configur
- Page 138 and 139: Figure 72: Signal Response Generato
- Page 140 and 141: For examples of interactive generat
- Page 142 and 143: quest of the same message must foll
- Page 144 and 145: 4.3 Replay Block 131 The replay blo
- Page 146 and 147:
4.5 Filter block 133 The volume of
- Page 148 and 149:
The filter configuration is lost wh
- Page 150 and 151:
Note: When a CAPL node is removed f
- Page 152 and 153:
139 The left side of the dialog is
- Page 154 and 155:
Figure 79: The Panel Editor 141 All
- Page 156 and 157:
143 Note: It is now possible to aut
- Page 158 and 159:
5.3.2 Configuration of the Elements
- Page 160 and 161:
147 Only elements completely enclos
- Page 162 and 163:
With View you can choose among thre
- Page 164 and 165:
Figure 83: Configuration Dialog for
- Page 166 and 167:
5.9 Panel Control 153 For complex C
- Page 168 and 169:
155 Therefore, you can utilize a CA
- Page 170 and 171:
Bus event: Keyboard event: Time eve
- Page 172 and 173:
6.2.1 Opening Browser 159 Browser i
- Page 174 and 175:
161 If you are using more than one
- Page 176 and 177:
Bus Bus bus name Database Database
- Page 178 and 179:
8.4 LIN Specifications CANoe.LIN su
- Page 180 and 181:
9 Option .MOST In this chapter you
- Page 182 and 183:
9.5 Original timestamp 169 This is
- Page 184 and 185:
• Make sure, the DTD file is not
- Page 186 and 187:
9.7.4.1 Lookup Key 173 The data str
- Page 188 and 189:
9.8 Interactive Generator Block MOS
- Page 190 and 191:
9.10 Busstatistic Window 177 The bu
- Page 192 and 193:
179 mostLightLockError Most_Error E
- Page 194 and 195:
9.12.5 Hardware API 9.12.5.1 Optoly
- Page 196 and 197:
XOR Filter long MostSetXorFilter( )
- Page 198 and 199:
9.13.3 MOST XML Catalog 185 The dem
- Page 200 and 201:
9.14.8 Weird Spurious Events from M
- Page 202 and 203:
10 Option .FlexRay In this chapter
- Page 204 and 205:
11 Index ! ! Load symbol · 53 < k
- Page 206 and 207:
Error frame · 41, 64, 95, 119, 123
- Page 208 and 209:
R Radio button · 5 Raw value · 13