68<br />

2.7.4.1 Flow Control in Offline Mode<br />

The following functions of the main Start menu are available to you in Offline mode to<br />

track the recorded bus proceedings on the screen in slow motion:<br />

Start<br />

Reset<br />

Animate<br />

Break<br />

Step<br />

The individual messages of the data source are read-out and are sent as<br />

quickly as possible through the components of the measurement setup. In Offline<br />

mode the measurement can be resumed after a break. Reset must be<br />

called for a new start.<br />

After a measurement has been run through either partially or completely in Offline<br />

mode, it can be reset to the beginning again with Reset and can thereby be<br />

studied from the beginning again.<br />

Instead of reading data from the source file as quickly as possible, in Animate<br />

mode only about 3 entries per second are read from the source file. This results<br />

in a slow-motion representation of the processes. All of the display windows<br />

may be active during this process, e.g. so that the user can easily observe the<br />

sequence of messages in the Trace window. The Animate run can be interrupted<br />

by the key or the menu command Start│Break. The speed of the<br />

Animate mode can be set with the following line in section [Offline] of the<br />

file CAN.INI:<br />

AnimationDelay=nnn<br />

where nnn describes the time between the replay of two successive events in<br />

milliseconds. (The default value is 300 [ms])<br />

In Offline mode this menu item interrupts the replay of data from the source file<br />

(Animate run). The same can be achieved by the key. A restart resumes<br />

the replay at the point where it was interrupted by Break.<br />

This menu item (or the key) causes a single step of the measurement to<br />

be run. Each time this is activated only one additional message is read from the<br />

log file and processed in the data flow plan.<br />

Within a measurement the user can switch back and forth whenever desired between<br />

Start, Animate and Step.<br />

2.7.4.2 Configuration of Online and Offline Modes<br />

In principle, there are different measurement setups and completely separate parameter<br />

sets for Online and Offline modes, so that the two modes - including their<br />

window layouts - can be configured differently.<br />

© Vector Informatik GmbH <strong>CANoe</strong>/<strong>DENoe</strong> Manual Version 4.1.1