68<br />
2.7.4.1 Flow Control in Offline Mode<br />
The following functions of the main Start menu are available to you in Offline mode to<br />
track the recorded bus proceedings on the screen in slow motion:<br />
Start<br />
Reset<br />
Animate<br />
Break<br />
Step<br />
The individual messages of the data source are read-out and are sent as<br />
quickly as possible through the components of the measurement setup. In Offline<br />
mode the measurement can be resumed after a break. Reset must be<br />
called for a new start.<br />
After a measurement has been run through either partially or completely in Offline<br />
mode, it can be reset to the beginning again with Reset and can thereby be<br />
studied from the beginning again.<br />
Instead of reading data from the source file as quickly as possible, in Animate<br />
mode only about 3 entries per second are read from the source file. This results<br />
in a slow-motion representation of the processes. All of the display windows<br />
may be active during this process, e.g. so that the user can easily observe the<br />
sequence of messages in the Trace window. The Animate run can be interrupted<br />
by the key or the menu command Start│Break. The speed of the<br />
Animate mode can be set with the following line in section [Offline] of the<br />
file CAN.INI:<br />
AnimationDelay=nnn<br />
where nnn describes the time between the replay of two successive events in<br />
milliseconds. (The default value is 300 [ms])<br />
In Offline mode this menu item interrupts the replay of data from the source file<br />
(Animate run). The same can be achieved by the key. A restart resumes<br />
the replay at the point where it was interrupted by Break.<br />
This menu item (or the key) causes a single step of the measurement to<br />
be run. Each time this is activated only one additional message is read from the<br />
log file and processed in the data flow plan.<br />
Within a measurement the user can switch back and forth whenever desired between<br />
Start, Animate and Step.<br />
2.7.4.2 Configuration of Online and Offline Modes<br />
In principle, there are different measurement setups and completely separate parameter<br />
sets for Online and Offline modes, so that the two modes - including their<br />
window layouts - can be configured differently.<br />
© Vector Informatik GmbH <strong>CANoe</strong>/<strong>DENoe</strong> Manual Version 4.1.1