9.14.4 Warning ‘2 Tx receipt(s) got lost’<br />
When sending MOST frames in quick succession through the Optolyzer box, the<br />
driver may lose Tx receipts for sending requests. Therefore, <strong>CANoe</strong> cannot affirm<br />
whether a frame has been sent or not. The warning ‘N Tx receipt(s) got lost’ will be<br />
written in the Write window as soon as an incoming Tx receipt indicates, that N former<br />
Tx receipts are missing.<br />
In general, this warning occurs on send requests to a node address that does not<br />
exist in the MOST ring. Please check the destination address and reduce the sending<br />
frequency.<br />
9.14.5 After several minutes <strong>CANoe</strong> doesn’t receive or send any MOST Frames<br />
After several minutes <strong>CANoe</strong> doesn’t receive or send any MOST Frames. The CAN<br />
related features of <strong>CANoe</strong> still work stable.<br />
Please check:<br />
• Are the COM port settings in the windows control panel correct?<br />
They must be 115.2 kBaud, 8 Bit, no parity, 1 Stop Bit, Hardware flow control<br />
• There may be problems with the installation of the OptoControl ActiveX Control<br />
Please try to reinstall the OptoControl. First deinstall OptoControl using Windows<br />
(Settings, Control Panel, Add/Remove Software). Ensure that there are no<br />
entries belonging to the OptoControl left in the registry (search for "*opto*").<br />
Than install OptoControl again. Use the version provided on the <strong>CANoe</strong> CD according<br />
to the used operating system (on the CD under Drivers\Optolyzer\OptoControl).<br />
9.14.6 Error ‘Port COM1 busy for channel 1’<br />
If the ActiveX can not open a connection to an Optolyzer box, this message appears<br />
at measurement start. The following reasons can cause this problem:<br />
• No Optolyzer is connected to the COM port configured, or<br />
• the Optolyzer is switched off, or<br />
• the COM port is already used by another application.<br />
If the Optolyzer was just recently connected to this computer or to <strong>CANoe</strong> Option<br />
MOST and is therefore started for the first time with <strong>CANoe</strong>, just try to start the measurement<br />
again or try switching the Optolyzer off and on again.<br />
Connection problems to the Optolyzer may also be solved by a re-start of <strong>CANoe</strong>.<br />
9.14.7 Error ‘No valid license for channel 1’<br />
<strong>CANoe</strong> cannot establish the connection to the Optolyzer interface box through the<br />
Optolyzer ActiveX Control because of an invalid license key. Please check:<br />
• The license key must include the activation for the hardware and the ActiveX<br />
Control.<br />
• The key has been entered correctly in the Install register of the MOST Hardware<br />
Configuration dialog. It must not contain white spaces or dashes.<br />
© Vector Informatik GmbH <strong>CANoe</strong>/<strong>DENoe</strong> Manual Version 4.1.1