16<br />

Figure 18: Statistics Window<br />

10 messages per second were recorded for identifier 64, and half as many were recorded<br />

for identifier 3FC. This result corresponds to the cyclic periods of 100 and 200<br />

milliseconds set in the generator blocks.<br />

If the Graphics window display is too imprecise, the statistics block offers you a statistical<br />

report that gives you more precise information on the transmit interval for each<br />

message. Stop the measurement and activate the statistical report in the configuration<br />

dialog of the Statistics block (Measurement Setup).<br />

Figure 19: Activate the statistical report<br />

If the Activate check box of the expanded statistical functions is selected, a Statistics<br />

report is generated for at least one acquisition range during the measurement. After<br />

the end of the measurement this can be output to the Write window by the Display<br />

statistics report command in the Statistics block's popup menu.<br />

© Vector Informatik GmbH <strong>CANoe</strong>/<strong>DENoe</strong> Manual Version 4.1.1