CANoe DENoe - KEMT FEI TUKE
CANoe DENoe - KEMT FEI TUKE
CANoe DENoe - KEMT FEI TUKE
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
107<br />
10x , n = [1 to 9], x = whole number). The lower and upper range limits are<br />
rounded-off to the precision of the Division value.<br />
Rounding always affects all signals of the Graphics window. The active mode<br />
(X-mode, Y-mode or XY-mode) is considered. Scaling of the signals is roundedoff<br />
to a whole number value.<br />
Get scalings/Store scalings<br />
Marker<br />
Grid<br />
Y-Axis<br />
You can save the scaling configuration of the Graphics window (i.e. the time<br />
range displayed for all signals and the value ranges of each individual signal) as<br />
a home configuration. The default home configuration has a time range from 0<br />
to 5 seconds and the Min/Max value range of each signal taken from the database.<br />
With the function Store scalings the current scaling of the active Graphics window<br />
is saved. In doing so, the active modes are considered (X-mode, Y-mode<br />
or XY-mode, and Single-Signal or Multisignal mode). Afterwards, you can reset<br />
all scalings in the Graphics window to this stored configuration at any time with<br />
the function Get Scalings.<br />
This command activates or deactivates measurement point marking. The color<br />
of the measurement points matches the preset signal color.<br />
This command enables/disables grid lines in the Graphics window. The grid<br />
lines match the subdivisions of the Y-axis. You can set the color of the grid lines<br />
in the Color Options dialog.<br />
This command enables/disables labeling of the Y-axis in the active Graphics<br />
window.<br />
When labeling is disabled, a Y-axis with 10 subdivisions is displayed for all signals.<br />
In the legend the following are shown for each signal: Lower and upper<br />
values of the viewing area, and the value amount between any two subdivision<br />
tick marks.<br />
If labeling is enabled, the subdivision of the Y-axis is calculated automatically for<br />
the active signal and is displayed in the color of the signal.<br />
The tick marks are set to whole number values. If a signal is shown as decimal<br />
(i.e. raw signal values without conversion), then only whole numbers are displayed.<br />
In this case, if an area between two adjacent numbers is shown magnified,<br />
no subdivision tick marks will be seen any longer along the Y-axis. For the<br />
physical display type subdivisions less than 1 are also shown.<br />
When labeling is enabled the legend also shows the following for each signal:<br />
Lower and upper values of the viewing area (i.e. not necessarily the values of<br />
the lowermost and uppermost Y-axis tick marks) and the value amount between<br />
any two tick marks.<br />
© Vector Informatik GmbH <strong>CANoe</strong>/<strong>DENoe</strong> Manual Version 4.1.1