The filter configuration is lost when a channel filter is removed from the measurement<br />

setup (Delete this node in the popup menu or with )<br />

Note: A channel filter which has not been configured can be used in the data<br />

flow plan to simply show the number of channels being used.<br />

4.7 CAPL Nodes in the Simulation Setup<br />

135<br />

A CAPL node is a universal function block whose characteristics the user defines by<br />

writing a CAPL program. CAPL nodes in the simulation setup are called Network<br />

nodes. Together with the real nodes they define the functionality of the overall system.<br />

A functional description of a network node includes the node's behavior with regard<br />

to input and output variables as well as messages to be received and transmitted.<br />

The event-driven, procedural language CAPL is provided in <strong>CANoe</strong> for modeling<br />

network nodes.<br />

When a new setup is created (Menu item File│New configuration), first the simulated<br />

bus (red line) and the real CAN bus (black line) are displayed in the simulation<br />

setup. The two buses are connected to one another via the card icon.<br />

Figure 77: Configuration Dialog for Network Node<br />

When you click the bus image with the right mouse button, the popup menu of the<br />

CAN bus appears. You can insert a network node in the simulation setup with the<br />

menu command Insert network node. This is displayed as a rectangular function<br />

© Vector Informatik GmbH <strong>CANoe</strong>/<strong>DENoe</strong> Manual Version 4.1.1