128<br />

nals of the messages can be configured individually in their signal lists. An alternative<br />

to activating the [New] button is to double click with the left mouse button in the first<br />

empty line of the message name column of the Message Explorer.<br />

Without a database you can transmit any desired messages by manually entering the<br />

CAN identifier of the desired message in the transmit list (Identifier column). To generate<br />

a new message click in the first empty cell of Identifier column with the left mouse<br />

button or press the [New] button. After selecting the desired number of data bytes<br />

for the message (DLC column) you can then input the data bytes (Data field columns).<br />

The signal list remains empty.<br />

Note: The [ErrorFrame] button can be used to enter an Error frame in the<br />

transmit list. This allows Error frames to be transmitted on the bus. Remote<br />

frames can be created from normal messages in the transmit list,<br />

except that in the Frame message parameter column the description<br />

Remote is selected instead of Data.<br />

4.2.1.2 Value Generator<br />

In addition to already existing messages/signals new generated signals can be<br />

transmitted too.<br />

The following generator types are available:<br />

• Toggle switch<br />

• Range of values<br />

• Ramps and pulses<br />

• Random<br />

• Sine<br />

• Environment variable<br />

• User defined<br />

You can find details for using the different types in the online help.<br />

4.2.1.3 Trigger Condition<br />

The trigger condition (Triggering columns) is, in contrast to the traditional generator<br />

block, entered separately for each message.<br />

You can choose between manual interactive triggering ([Send] button), key press<br />

(Key column) and interval-driven repetition (Timer; Cycle time column [ms]). Additionally,<br />

the user can configure the number of messages to be sent at the time of triggering<br />

(Burst column). The default value for Burst is 1, i.e. exactly one message is<br />

sent per triggering.<br />

4.2.1.4 Generating a High-Load Situation<br />

With the High load trigger condition you can induce a high load situation.<br />

A high bus load is reached when messages follow right after one another on the bus.<br />

To achieve this, after successful transmission of one message the next transmit re-<br />

© Vector Informatik GmbH <strong>CANoe</strong>/<strong>DENoe</strong> Manual Version 4.1.1