CANoe DENoe - KEMT FEI TUKE
CANoe DENoe - KEMT FEI TUKE
CANoe DENoe - KEMT FEI TUKE
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
• Make sure, the DTD file is not referenced within the XML catalog by removing<br />
the tag at the beginning of your XML file.<br />
• Disable the validation by setting the entry FCatImportValidate to 0 in the<br />
CAN.INI file ([MOST] section):<br />
[MOST]<br />
FCatImportValidate = 0<br />
Note: Using XML catalogs without any DTD or without the official DTD of the<br />
MOST Cooperation might lead to unpredictable import results!<br />
9.7.1.4 Import Errors and Warnings<br />
171<br />
The XML import of <strong>CANoe</strong> writes logical and semantical errors and other inconsistencies<br />
in the XML Function Catalog into an ASCII file if the entry FCatImport-<br />
Log=1 is set in the [MOST] section of the profile CAN.INI. The name of the ASCII file<br />
is determined by the name of the XML file concerned (same directory, suffix .xml<br />
replaced by .log).<br />
9.7.1.5 Using more than one XML Function Catalog<br />
<strong>CANoe</strong>.MOST can use several XML Function Catalogs simultaneously.<br />
If a MOST message is defined in more than one XML Function Catalog, the description<br />
with the highest precision will be used. The precision of a message description is<br />
internally defined as follows (4 = highest precision):<br />
0 FBlock of message is not described<br />
1 only FBlock of message is described<br />
2 message is described up to ‘Function’<br />
3 message is described up to ‘Operation’<br />
4 at least one parameter of the message is described<br />
If a message is described in XML Function Catalogs and in CANdb databases, CA-<br />
Noe.MOST uses the description according to the disassembly mode:<br />
• Disassembly mode 2: If a message is described in a CANdb database, this description<br />
will be used.<br />
• Disassembly mode 3: If the message description in the XML Function Catalog is<br />
of precision 3 or 4, this description will be used. Otherwise the description in the<br />
CANdb database will be used.<br />
9.7.1.6 Reading and Rereading XML files<br />
Importing a XML Function Catalog needs some time according to the size of the XML<br />
file. It needs some memory during parsing as well (approximately three to five times<br />
the size of the XML file). Therefore <strong>CANoe</strong>.MOST holds all information of the XML file<br />
in memory after parsing (the amount of memory needed after the parsing process is<br />
finished is approximately one to three times the size of the XML file).<br />
This memory is only released when<br />
© Vector Informatik GmbH <strong>CANoe</strong>/<strong>DENoe</strong> Manual Version 4.1.1