09.01.2013 Views

CANoe DENoe - KEMT FEI TUKE

CANoe DENoe - KEMT FEI TUKE

CANoe DENoe - KEMT FEI TUKE

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

In the Entire Measurement trigger mode the entire measurement is logged. Pretrigger<br />

and post-trigger times cannot be selected. Activating the button Write full<br />

buffer to file causes a full data buffer to be saved intermediately for long measurements.<br />

You can avoid data loss in this manner.<br />

Trigger<br />

Pretrig. Post-Trig.<br />

Log file<br />

Pretrig. Trigger n Trigger n+1 Post-Trig.<br />

Log file<br />

Time axis<br />

Time axis<br />

Figure 44: Time Window for the Trigger in Single Trigger Mode (top) and in Toggle-<br />

Trigger Mode (Bottom)<br />

In the Single Trigger trigger mode all those data occurring before and after a specific<br />

trigger is logged. You can enter the necessary settings for pretrigger and post-trigger<br />

times, and the number of triggers you wish to log, in the Time section.<br />

In Toggle Trigger trigger mode the time window is described by two successive triggers<br />

(start-of-block and end-of-block triggers). The first trigger activated during<br />

measurement is the start-of-block trigger, and the second is the end-of-block trigger.<br />

Afterwards, another start-of-block trigger follows, etc. The pre-trigger time in toggle<br />

trigger mode is referenced to the start-of-block trigger, and the post-trigger time is<br />

referenced to the end-of-block trigger. With the check box Use combined toggle<br />

mode you define, that for start-of-block and end-of-block trigger the same trigger<br />

conditions are valid.<br />

© Vector Informatik GmbH <strong>CANoe</strong>/<strong>DENoe</strong> Manual Version 4.1.1<br />

61

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!