CANoe DENoe - KEMT FEI TUKE
CANoe DENoe - KEMT FEI TUKE
CANoe DENoe - KEMT FEI TUKE
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
In the Entire Measurement trigger mode the entire measurement is logged. Pretrigger<br />
and post-trigger times cannot be selected. Activating the button Write full<br />
buffer to file causes a full data buffer to be saved intermediately for long measurements.<br />
You can avoid data loss in this manner.<br />
Trigger<br />
Pretrig. Post-Trig.<br />
Log file<br />
Pretrig. Trigger n Trigger n+1 Post-Trig.<br />
Log file<br />
Time axis<br />
Time axis<br />
Figure 44: Time Window for the Trigger in Single Trigger Mode (top) and in Toggle-<br />
Trigger Mode (Bottom)<br />
In the Single Trigger trigger mode all those data occurring before and after a specific<br />
trigger is logged. You can enter the necessary settings for pretrigger and post-trigger<br />
times, and the number of triggers you wish to log, in the Time section.<br />
In Toggle Trigger trigger mode the time window is described by two successive triggers<br />
(start-of-block and end-of-block triggers). The first trigger activated during<br />
measurement is the start-of-block trigger, and the second is the end-of-block trigger.<br />
Afterwards, another start-of-block trigger follows, etc. The pre-trigger time in toggle<br />
trigger mode is referenced to the start-of-block trigger, and the post-trigger time is<br />
referenced to the end-of-block trigger. With the check box Use combined toggle<br />
mode you define, that for start-of-block and end-of-block trigger the same trigger<br />
conditions are valid.<br />
© Vector Informatik GmbH <strong>CANoe</strong>/<strong>DENoe</strong> Manual Version 4.1.1<br />
61