6/23/04<br />

Attachment 3<br />

Page 26<br />

interconnection facility, Bell<strong>South</strong> will pay a monthly charge equal to one half of the<br />

<strong>TC</strong> SYTEMS-provided facility charge according to Bell<strong>South</strong> unbundled rate element<br />

for the facility used.<br />

4.4.15.3 Where the SPOI for the signaling link facilities is located at the <strong>TC</strong> SYTEMS Wire<br />

Center where the signaling link facilities terminate and Bell<strong>South</strong> has furnished the<br />

interconnection facility, <strong>TC</strong> SYTEMS will pay a monthly charge equal to one half of<br />

the Bell<strong>South</strong>-provided facility charge according to Bell<strong>South</strong> unbundled rate element<br />

for the facility used.<br />

4.4.16 Each party is responsible for all facility maintenance and provisioning on its side of the<br />

SPOI.<br />

4.4.17 Implementation of new interconnection arrangements (as opposed to augmentation of<br />

existing arrangements) will include testing consistent with industry standards. Testing<br />

of SS7 interconnection shall include completion of all tests described in CCS Network<br />

Interconnection Testing documents defined by the Internetwork Interoperability Test<br />

Plan (IITP).<br />

5. Message Screening<br />

5.1 Bell<strong>South</strong> shall set message screening parameters so as to accept messages from <strong>TC</strong><br />

SYTEMS local or tandem switching systems destined to any signaling point in the<br />

Bell<strong>South</strong> SS7 network or any network interconnected to the Bell<strong>South</strong> SS7 network<br />

with which the <strong>TC</strong> SYTEMS switching system has a legitimate signaling relationship.<br />

5.2 Bell<strong>South</strong> shall set message screening parameters so as to accept messages destined<br />

to/from an <strong>TC</strong> SYTEMS local or tandem switching system or to/from an <strong>TC</strong><br />

SYTEMS Service Control Point (SCP) from any signaling point or network<br />

interconnected to the Bell<strong>South</strong> SS7 network with which the <strong>TC</strong> SYTEMS switching<br />

system has a legitimate signaling relationship.<br />

6 STP Requirements<br />

6.1 Bell<strong>South</strong> shall provide Message Transfer Part (MTP) and Signaling Connection<br />

Control Point (SCCP) protocol interfaces in accordance with sections relevant to the<br />

MTP or SCCP in the following specifications:<br />

6.2 Bellcore GR-905-CORE, Issue 1 [or its successor(s)] Common Channel Signaling<br />

Network Interface Specification (CCSNIS) Supporting Network Interconnection<br />

(SNI), MTP, and Integrated Services Digital Network User Part (ISDNUP).<br />

7. SS7 Network Interconnection<br />

7.1 SS7 Network Interconnection (see Figure 1 below) is the interconnection of <strong>TC</strong><br />

SYTEMS Signaling Transfer Points (STPs) and <strong>TC</strong> SYTEMS local or tandem<br />

switching systems with the Bell<strong>South</strong> STPs. This interconnection provides<br />

connectivity that enables the exchange of SS7 messages among Bell<strong>South</strong> switching<br />