09.08.2013 Views

TC Systems, Inc. South Carolina - AT&T Clec Online

TC Systems, Inc. South Carolina - AT&T Clec Online

TC Systems, Inc. South Carolina - AT&T Clec Online

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Version 2Q03: 07/21/03<br />

Attachment 4 - Remote Site<br />

Page 22<br />

7.10 Cancellation. If at any time prior to space acceptance, <strong>TC</strong> SYSTEMS cancels its<br />

order for the Remote Collocation Space(s) (Cancellation), Bell<strong>South</strong> will bill the<br />

applicable nonrecurring rate(s) as set forth in Exhibit B for any and all work processes<br />

for which work has begun or been completed. In no event will the charges billed by<br />

Bell<strong>South</strong> exceed the maximum amount <strong>TC</strong> SYSTEMS would have otherwise paid for<br />

the work undertaken by Bell<strong>South</strong> if no cancellation of the order had occurred.<br />

7.11 Licenses. <strong>TC</strong> SYSTEMS, at its own expense, will be solely responsible for obtaining<br />

from governmental authorities, and any other appropriate agency, entity, or person, all<br />

rights, privileges, and licenses necessary or required to operate as a provider of<br />

telecommunications services to the public or to build-out, equip and occupy the<br />

Remote Collocation Space.<br />

7.12 Environmental Hazard Guidelines. The Parties agree to utilize and adhere to the<br />

Environmental Hazard Guidelines identified in Exhibit A attached hereto.<br />

8 Rates and Charges<br />

8.1 Application Fee. Bell<strong>South</strong> shall assess an Application Fee via a service order, which<br />

shall be issued at the time Bell<strong>South</strong> responds that space is available pursuant to<br />

Section 6.9 (Application Response). This nonrecurring fee will be billed by Bell<strong>South</strong><br />

on the date that Bell<strong>South</strong> provides an Application Response.<br />

8.2 Rack/Bay Space. The rack/bay space charge includes reasonable charges for air<br />

conditioning, ventilation and other allocated expenses associated with maintenance of<br />

the Remote Site Location, and includes amperage necessary to power <strong>TC</strong> SYSTEMS’s<br />

equipment. <strong>TC</strong> SYSTEMS shall pay rack/bay space charges based upon the number of<br />

racks/bays requested. Bell<strong>South</strong> will assign Remote Collocation Space in conventional<br />

remote site rack/bay lineups where feasible.<br />

8.3 Power. Bell<strong>South</strong> shall make available –48 Volt (-48V) DC power for <strong>TC</strong><br />

SYSTEMS’s Remote Collocation Space at a Bell<strong>South</strong> Power Board or Bell<strong>South</strong><br />

Battery Distribution Fuse Bay (BDFB) at <strong>TC</strong> SYSTEMS’s option within the Remote<br />

Site Location. The charge for power shall be assessed as part of the recurring charge<br />

for rack/bay space. If the power requirements for <strong>TC</strong> SYSTEMS’s equipment exceeds<br />

the capacity available, then such power requirements shall be assessed on an individual<br />

case basis. Bell<strong>South</strong> will revise recurring power charges to reflect a power upgrade<br />

upon notification of the completion of the upgrade by <strong>TC</strong> SYSTEMS’s Bell<strong>South</strong><br />

Certified Vendor. Bell<strong>South</strong> will revise recurring power charges to reflect a power<br />

reduction upon Bell<strong>South</strong>’s receipt of the Power Reduction Form from <strong>TC</strong> SYSTEMS<br />

certifying the completion of the power reduction, including the removal of the power<br />

cabling by <strong>TC</strong> SYSTEMS’s Bell<strong>South</strong> Certified Supplier.<br />