Version 3Q03: 11/12/2003<br />

BST 09/29/05 AL<br />

Attachment 2<br />

Page 14<br />

2.1.5 Bell<strong>South</strong> will only provision, maintain and repair the Loops to the standards that<br />

are consistent with the type of Loop ordered, and at parity with the standards<br />

provided to Bell<strong>South</strong> retail end users.<br />

2.1.5.1 When a Bell<strong>South</strong> technician is required to be dispatched to provision the Loop,<br />

Bell<strong>South</strong> will tag the Loop with the Circuit ID number and the name of the<br />

ordering CLEC at no charge to the CLEC. When a dispatch is not required to<br />

provision the Loop, Bell<strong>South</strong> will tag the Loop on the next required visit to the<br />

end user’s location. If <strong>TC</strong> SYSTEMS wants to ensure the Loop is tagged during<br />

the provisioning process for Loops that do not require a dispatch (e.g. UVL-SL1,<br />

UVL-SL2, and UCL-ND), <strong>TC</strong> SYSTEMS may order Loop Tagging. Rates for<br />

Loop Tagging are as set forth in Exhibit A of this Attachment.<br />

2.1.5.2 In the event Bell<strong>South</strong> must dispatch to the end user’s location more than once<br />

due to incorrect or incomplete information provided by <strong>TC</strong> SYSTEMS (e.g.,<br />

incomplete address, incorrect contact name/number, etc.), Bell<strong>South</strong> will bill <strong>TC</strong><br />

SYSTEMS for each additional dispatch required to provision the circuit due to the<br />

incorrect/incomplete information provided. Bell<strong>South</strong> will assess the applicable<br />

Maintenance of Service rates as set forth in the rate Exhibit 1 below. In the event<br />

that the Bell<strong>South</strong> technician misreads, misconnects, mislabels, and is required to<br />

redispatch to complete the order, Bell<strong>South</strong> shall bear the cost of the redispatch.<br />

Exhibit 1<br />

Rates for Dispatch Due to <strong>Inc</strong>omplete or <strong>Inc</strong>orrect Information<br />

AL FL GA KY LA MS NC SC TN<br />

POTS Basic $19.67 $20.52 $30.44 $20.52 $19.44 $19.72 $19.44 $19.69 $19.44<br />

OT $23.29 $24.14 $34.06 $24.14 $23.06 $23.34 $23.06 $23.44 $23.06<br />

Premium $26.90 $27.75 $37.67 $27.75 $26.67 $26.95 $26.67 $26.92 $26.67<br />

Special<br />

Service<br />

Basic $21.98 $22.83 $32.75 $22.83 $21.75 $22.03 $21.75 $22.00 $21.75<br />

OT $26.39 $27.24 $37.16 $27.24 $26.16 $26.44 $26.16 $26.41 $26.16<br />

Premium $30.79 $31.64 $41.56 $31.64 $30.56 $30.84 $30.56 $30.81 $30.56<br />

2.1.6 Loop Testing/Trouble Reporting<br />

2.1.6.1 For UNE Loops, <strong>TC</strong> SYSTEMS will be responsible for testing and isolating<br />

troubles on the Loops. <strong>TC</strong> SYSTEMS must test and isolate trouble to the<br />

CCCS 95 of 433