Attachment 4-Central Office<br />

Page 18<br />

name and pairs and the POT frame name, RR#, and row (shelf letter) and vertical<br />

range of the POT it is connected to. (Note that the Bell<strong>South</strong> vendor cannot wire<br />

between the cross-connectable POT and the COSMIC until the output of the MELD<br />

run is available; he must wire it as shown on that output.) This labeling is to be done<br />

by the Bell<strong>South</strong> vendor placing the cabling between the POT and the Bell<strong>South</strong><br />

MDF/COSMIC frame.<br />

5.11.1.2 For a DS1, DS3 or fiber interface at a collocation arrangement, stenciling or labeling<br />

at the POT and at the Bell<strong>South</strong> frames should be done in the following manner:<br />

With a non-cross-connectable POT (cross-connectable POT is not available for these<br />

levels of service), label the POT frame (or panel(s)) with its frame name, relay rack<br />

number, and shelf/panel designations; label them with the collocator’s ACNA (CCNA)<br />

also. Label each POT panel with the Bell<strong>South</strong> DSX/LGX bay, panel, and jack #s to<br />

which they are wired. Label the Bell<strong>South</strong> DSX/LGX panels with the POT frame<br />

name, relay rack #, shelf/panel, and jack #s to which they are wired. This labeling is to<br />

be done by the Bell<strong>South</strong> vendor placing the cabling between the POT and the<br />

Bell<strong>South</strong> DSX/LGX frames.<br />

5.11.2 When a POT bay is NOT used<br />

5.11.2.1 For a DS0 interface, stenciling and labeling on the Bell<strong>South</strong> MDF and COSMIC<br />

frames and the DS0 POT bays should be done as follows:<br />

• Label the MDF frame blocks with the cable and pair name and count, the relay rack<br />

number of the collocator’s equipment, and the collocator’s ACNA. The collocator’s<br />

equipment should be labeled in the same manner that Bell<strong>South</strong>’s own equipment is<br />

labeled. This must be done by the collocator’s vendor (who will be placing the cabling<br />

between the collocator and the Bell<strong>South</strong> MDF).<br />

5.11.2.2 For a DS1, DS3 or fiber interface, stenciling or labeling at the POT and at the<br />

Bell<strong>South</strong> frames should be done in the following manner:<br />

• Label the Bell<strong>South</strong> DSX/LGX panels with the relay rack number of the collocator’s<br />

equipment, the collocator’s ACNA, and the TIE carrier (T1TIE/T3TIE) or fiber cable<br />

(fiber) IDs. The collocator’s equipment should be labeled in the same manner that<br />

Bell<strong>South</strong>’s own equipment is labeled. This labeling is to be done by the collocator’s<br />

vendor (who will be placing the cabling between the collocator and the Bell<strong>South</strong><br />

DSX/LGX frames).<br />

5.12 Verification and Testing of Intra-office Wiring (Post Delivery of Collocation<br />

Space)<br />

5.12.1 Whenever <strong>TC</strong> SYSTEMS is responsible for either the installation, testing and/or<br />

maintenance of any intra-office wiring that directly connects the <strong>TC</strong> SYSTEMS<br />

collocation space to the Bell<strong>South</strong> Main Distribution Frame (MDF), when it is the<br />

demarcation point, <strong>TC</strong> SYSTEMS has the option of performing verification and<br />

Version 2Q03: 07/21/03-<strong>TC</strong> SYSTEMS AL<br />

CCCS 244 of 433