Version 2Q03: 07/21/03-<strong>TC</strong> SYSTEMS AL<br />

Attachment 4-Central Office<br />

Page 5<br />

requested and the measures Bell<strong>South</strong> is taking to make additional space available for<br />

collocation arrangements. A Space Availability Report does not reserve space at the<br />

Bell<strong>South</strong> Premises for which the Space Availability Report was requested by <strong>TC</strong><br />

SYSTEMS.<br />

The request from <strong>TC</strong> SYSTEMS for a Space Availability Report must be in writing<br />

and include the Bell<strong>South</strong> Premises street address, as identified in the Local Exchange<br />

Routing Guide (LERG) and Common Language Location Identification (CLLI) code<br />

of the Bell<strong>South</strong> Premises. CLLI code information is located in the National<br />

Exchange Carrier Association (NECA) Tariff FCC No. 4.<br />

2.1.2 Bell<strong>South</strong> will respond to a request for a Space Availability Report for a particular<br />

Bell<strong>South</strong> Premises within ten (10) calendar days of receipt of such request.<br />

Bell<strong>South</strong> will respond in ten (10) calendar days to a request for a Space Availability<br />

Report for up to and including five (5) Bell<strong>South</strong> Premises within the same state. The<br />

response time for a request for a Space Availability Report of more than five (5)<br />

Bell<strong>South</strong> Premises shall be negotiated between the Parties. If Bell<strong>South</strong> cannot meet<br />

the ten (10) calendar-day response time, Bell<strong>South</strong> shall notify <strong>TC</strong> SYSTEMS and<br />

inform <strong>TC</strong> SYSTEMS of the time frame under which it can respond.<br />

3. Collocation Options<br />

3.1 Cageless. Bell<strong>South</strong> shall allow <strong>TC</strong> SYSTEMS to collocate <strong>TC</strong> SYSTEMS’s<br />

equipment and facilities without requiring the construction of a cage or similar<br />

structure. Bell<strong>South</strong> shall allow <strong>TC</strong> SYSTEMS to have direct access to <strong>TC</strong><br />

SYSTEMS’s equipment and facilities in accordance with Section 5.9. Bell<strong>South</strong> shall<br />

make cageless collocation available in single bay increments. Except where <strong>TC</strong><br />

SYSTEMS’s equipment requires special technical considerations (e.g., special cable<br />

racking or isolated ground plane), Bell<strong>South</strong> shall assign cageless Collocation Space in<br />

conventional equipment rack lineups where feasible. For equipment requiring special<br />

technical considerations, <strong>TC</strong> SYSTEMS must provide the equipment layout, including<br />

spatial dimensions for such equipment pursuant to generic requirements contained in<br />

Telcordia GR-63-Core, and shall be responsible for compliance with all special<br />

technical requirements associated with such equipment.<br />

3.2 Caged. At <strong>TC</strong> SYSTEMS’s expense, <strong>TC</strong> SYSTEMS will arrange with a Supplier<br />

certified by Bell<strong>South</strong> (Bell<strong>South</strong> Certified Supplier) to construct a collocation<br />

arrangement enclosure in accordance with Bell<strong>South</strong>’s Technical References (TRs)<br />

(hereinafter referred to as Specifications) prior to starting equipment installation.<br />

Bell<strong>South</strong> will provide Specifications upon request. Where local building codes<br />

require enclosure specifications more stringent than Bell<strong>South</strong>’s enclosure<br />

Specifications, <strong>TC</strong> SYSTEMS and <strong>TC</strong> SYSTEMS’s Bell<strong>South</strong> Certified Supplier must<br />

comply with the more stringent local building code requirements. <strong>TC</strong> SYSTEMS’s<br />

Bell<strong>South</strong> Certified Supplier shall be responsible for filing and obtaining any and all<br />

necessary permits and/or licenses for such construction. Bell<strong>South</strong> shall cooperate<br />