General Instructions.<br />

-<br />

Platelayers' Trolleys Continued. Going Into or Through Tunnels.<br />

General Rule 249 and B.T.R. 9.<br />

The 'following is a complete list of the<br />

Instruction contained in Block Telegraph<br />

applied :—<br />

Tunnel. Length.<br />

Miles. Yards.<br />

Arthington, Bramhope<br />

Burdale • • •<br />

•<br />

•<br />

2<br />

0<br />

241<br />

1745<br />

Burton Salmon, Brotherton • 0 319<br />

Grinkle • • 0 993<br />

Harrogate, Crimple • 0 825<br />

Kettleness • 0 308<br />

Ravenscar • • 0 279<br />

Sandsend • • • 0 1652<br />

Scarborough, Gallows Close • 0 260<br />

Scotswood • • 0 269<br />

,Shildon • • 0 1217<br />

Sunderland • • 0 1116<br />

Tynemouth • 0 786<br />

Walker • 0 182<br />

Station Masters<br />

Inspector at once<br />

full particulars to<br />

FIRES AT STATIONS.<br />

General Rule 26&<br />

tunnels to which the Special<br />

Regulation No. 9 must be<br />

Remarla.<br />

187<br />

Between the hours of 3-30 and 7-30<br />

a.m. on week-days except Mondays,<br />

and from 3-0 a.m. to 6-0 a.m. on<br />

Mondays, when the Engineer has<br />

possession of the tip line through<br />

the tunnel platelayers' trolleys will<br />

not be signalled on the block<br />

instruments.<br />

and all concerned must advise the Permanent Way<br />

of any outbreak or fire, and must afterwards report<br />

the District Superintendent and Divisional Firemaster.<br />

(O. 2710). (0. 6085.)<br />

OBSTRUCTIONS PLACED IN CLOSE PROXIMITY TO LINES.<br />

General Rule 270 (c).<br />

Coal, cinders or other obstructions, other than permanent way materials<br />

required in connection with relaying, etc., must not, where it can possibly<br />

be avoided, be placed or allowed to accumulate within a space of 4 feet<br />

6 inches from any running line or siding, especially in Goods Yards or any<br />

places where shunting is carried on. ( O . 7160)<br />

VEHICLES CONTAINING EXPLOSIVES ON FREIGHT TRAINS.<br />

General Rules 279 and 206. -<br />

In the case of a vehicle or vehicles containing explosives being attached<br />

to a Freight train or engine, the Guard or <strong>Shunt</strong>er in charge must so inform<br />

the Driver, and must also tell him when and where such vehicle or vehicles<br />

will be detached en route. ( O . 7110).