Site Requirements and Specifications 2<br />

Physical Specifications<br />

Physical Specifications<br />

Table 2<br />

Physical specifications<br />

Type Specification Comments<br />

Weight<br />

Dimensions<br />

(width × depth × height)<br />

35 kg (77.2 lbs)<br />

350 x 510 x 590 mm<br />

(13.8 x 20.1 x 23.2 inches)<br />

Line voltage 100–240 VAC ± 10% Wide-ranging capability<br />

Line frequency 50 or 60 Hz ± 5%<br />

Power consumption 350 VA / 300 W / 1024 BTU/h Maximum<br />

Ambient operating<br />

temperature<br />

Ambient non-operating<br />

temperature<br />

5–40 °C (41–104 °F)<br />

-40 <strong>to</strong> 70°C (-40 <strong>to</strong> 158 °F)<br />

Humidity below 80% at 31 °C (87.8 °F) Non-condensing<br />

Operating altitude<br />

External cooling<br />

Up <strong>to</strong> 2000 m (6500 ft)<br />

max. 0.5 bar (7.2 psi),<br />

max. 50 °C (122 °F)<br />

Waterbath<br />

External pressure 2-12 bar (29-174 psi) Oil-free air or nitrogen<br />

Safety standards: IEC,<br />

CSA, UL<br />

Housing<br />

Installation category II,<br />

Pollution degree 2<br />

All materials are recyclable<br />

For indoor use only<br />

For applications run in CEC mode (<strong>Capillary</strong> Electrochroma<strong>to</strong>graphy) or CE+p<br />

mode (<strong>Capillary</strong> <strong>Electrophoresis</strong> mode with optional usage of higher pressure), an<br />

external pressure supply of oil-free air or nitrogen with a maximum pressure of 15<br />

bar (218 psi) can be used. A respective male adapter that fits in<strong>to</strong> <strong>the</strong> instrument’s<br />

female adapter and PTFE tubing are part of <strong>the</strong> shipment.<br />

NOTE<br />

The <strong>Agilent</strong> <strong>7100</strong> <strong>Capillary</strong> <strong>Electrophoresis</strong> <strong>System</strong> is designed <strong>to</strong> operate in a typical<br />

electromagnetic environment where RF transmitters, such as mobile phones, should not be<br />

used in close proximity.<br />

<strong>Agilent</strong> <strong>7100</strong> <strong>Capillary</strong> <strong>Electrophoresis</strong> <strong>System</strong> User Manual 21

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!