5 Using <strong>the</strong> <strong>Agilent</strong> <strong>7100</strong> <strong>Capillary</strong> <strong>Electrophoresis</strong> <strong>System</strong><br />

<strong>Capillary</strong> <strong>Electrophoresis</strong>, CE<br />

<strong>Capillary</strong> <strong>Electrophoresis</strong>, CE<br />

How <strong>to</strong> Use Your <strong>Agilent</strong> CE Instrument for <strong>Capillary</strong><br />

<strong>Electrophoresis</strong> Separations<br />

This chapter introduces method parameters for applications running in CE<br />

mode. This mode is <strong>the</strong> most suitable for applications in <strong>the</strong> field of capillary<br />

zone electrophoresis (CZE), micellar electrokinetic chroma<strong>to</strong>graphy (MEKC)<br />

and capillary isoelectric focussing (CIEF). The current CE mode for your<br />

instrument can be selected under Instrument < more CE < Instrument<br />

configuration... . The current mode is visible in <strong>the</strong> second line of <strong>the</strong> CE control<br />

diagram. For detailed information, see “Working with <strong>the</strong> CE Diagram” on<br />

page 84 and “Graphical User Interface Explanation” on page 86.<br />

<strong>Agilent</strong> CE Method Parameters<br />

This section describes <strong>the</strong> parameters of an <strong>Agilent</strong> CE method for data<br />

acquisition and <strong>the</strong>ir meanings. Example sets of parameters for a method <strong>to</strong><br />

analyze <strong>the</strong> test sample are in “Setting Up a Test Sample Run” on page 252.<br />

After you have completely set up <strong>the</strong> <strong>Agilent</strong> CE method and supplied <strong>the</strong><br />

sample information, you can run your method. Choose Run Method from <strong>the</strong><br />

Run control menu.<br />

Overview<br />

A convenient way <strong>to</strong> access <strong>the</strong> parameters of an <strong>Agilent</strong> CE method is <strong>the</strong><br />

item Setup Instrument Method in <strong>the</strong> Instrument menu. This displays <strong>the</strong> CE<br />

Method Setup dialog box. Tabs with parameters for <strong>the</strong> DAD and CE part of a<br />

method can be edited on this screen. The left-hand side shows <strong>the</strong> most<br />

important parameters. The right-hand side offers several pages that can be<br />

expanded subsequently for editing.<br />

92 <strong>Agilent</strong> <strong>7100</strong> <strong>Capillary</strong> <strong>Electrophoresis</strong> <strong>System</strong> User Manual