5 Using <strong>the</strong> <strong>Agilent</strong> <strong>7100</strong> <strong>Capillary</strong> <strong>Electrophoresis</strong> <strong>System</strong><br />

Controlling <strong>the</strong> <strong>Agilent</strong> CE Instrument<br />

Table 22<br />

Color<br />

No color<br />

Green<br />

Yellow<br />

Red<br />

Status LED color<br />

Meaning<br />

Instrument is ready<br />

Analysis running, do not use instrument with <strong>the</strong> exception of manual<br />

operation of <strong>the</strong> tray. Some fields in DAD and CE diagram are shaded gray.<br />

Not-ready condition. The run cannot be started yet. When you start, <strong>the</strong><br />

LED will come on after a certain time. Click <strong>the</strong> <strong>Agilent</strong> CE <strong>System</strong> status<br />

bar in <strong>the</strong> ChemStation <strong>to</strong> see what is not ready (for example<br />

temperature).<br />

Error condition. There was or is currently a problem with <strong>the</strong> instrument<br />

or communication <strong>to</strong> <strong>the</strong> PC, which requires your action or an<br />

acknowledgement. To get more information, connect <strong>to</strong> <strong>the</strong> instrument<br />

with <strong>the</strong> Lab Advisor or ChemStation software. Check <strong>the</strong> logbook.<br />

NOTE<br />

A blinking red LED indicates <strong>the</strong> instrument is in a resident mode. This means only a core of<br />

<strong>the</strong> firmware is active and <strong>the</strong> instrument has limited functionality. The Lab Advisor<br />

software will be able <strong>to</strong> connect <strong>to</strong> <strong>the</strong> instrument under <strong>the</strong>se circumstances. An<br />

instrument restart by switching <strong>the</strong> power off and on again boots with complete firmware<br />

loaded. During a main firmware download (see “Firmware” on page 176), <strong>the</strong> instrument<br />

shows a red blinking LED.<br />