Using <strong>the</strong> <strong>Agilent</strong> <strong>7100</strong> <strong>Capillary</strong> <strong>Electrophoresis</strong> <strong>System</strong> 5<br />

<strong>Capillary</strong> <strong>Electrophoresis</strong>, CE<br />

Cassette Temperature<br />

The cassette temperature can ei<strong>the</strong>r be set <strong>to</strong> not be controlled or <strong>to</strong> a certain<br />

setpoint. This setpoint must be within <strong>the</strong> instrument’s specified range (see<br />

“Physical Specifications” on page 21).<br />

The lowest applicable temperature is 10 °C below ambient temperature. The<br />

highest temperature is 60 °C.<br />

The instrument is ready after <strong>the</strong> cassette temperature reaches <strong>the</strong> setpoint<br />

and stabilizes. A run can be started<br />

The home values are activated at five points in your analysis:<br />

• When a method is loaded.<br />

• When you activate Run Method or Run Sequence from <strong>the</strong> RunControl menu.<br />

• After injection is completed.<br />

• After <strong>the</strong> s<strong>to</strong>ptime has elapsed.<br />

• After <strong>the</strong> entire analysis (including postconditioning) is completed.<br />

NOTE<br />

Keep <strong>the</strong> cassette temperature above <strong>the</strong> dew point or decrease <strong>the</strong> ambient humidity.<br />

The instrument is specified <strong>to</strong> be operated at non-condensing conditions which is at<br />

humidity below 80% at 31 °C (87.8 °F). Please be aware: if <strong>the</strong> temperature of <strong>the</strong> cassette<br />

is below <strong>the</strong> dew point condensation might take place. Subsequently water condensate<br />

from <strong>the</strong> ambient might lead <strong>to</strong> arcing and damage of <strong>the</strong> cassette or instrument.<br />