11.07.2015 Views

Applied Biosystems 7900HT Fast Real-Time PCR System and SDS ...

Applied Biosystems 7900HT Fast Real-Time PCR System and SDS ...

Applied Biosystems 7900HT Fast Real-Time PCR System and SDS ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Operating the Software without an <strong>SDS</strong> Enterprise DatabaseStarting <strong>and</strong> Configuring the Automation Controller Software for OperationStarting <strong>and</strong>Configuring theSoftwareThe <strong>Applied</strong> <strong>Biosystems</strong> <strong>7900HT</strong> <strong>Fast</strong> <strong>Real</strong>-<strong>Time</strong> <strong>PCR</strong> <strong>System</strong> employs theAutomation Controller Software for automated operation of the <strong>7900HT</strong> instrument.The software coordinates the action of the <strong>7900HT</strong> instrument, the bar code reader,<strong>and</strong> the Plate H<strong>and</strong>ler while acquiring <strong>and</strong> saving raw data during each run.1. If running the <strong>SDS</strong> software, do one of the following:• Select Instrument > Disconnect to discontinue communication betweenthe software <strong>and</strong> the instrument, or• Select File > Exit to close the <strong>SDS</strong> software.2. Start the Automation Controller Software(select > Programs > <strong>Applied</strong> <strong>Biosystems</strong> > <strong>SDS</strong> 2.2.1 >Automation Controller 2.2).3. If using the <strong>SDS</strong> Enterprise Database, enter your user name <strong>and</strong> password inthe appropriate fields of the Automation Controller Log In dialog box, thenclick .4. If using the <strong>SDS</strong> Enterprise Database, specify the Session-Study associations asdescribed in “Associating Session <strong>and</strong> Study Data” on page 4-33.5. If running the Automation Controller Software using the plate queue, verify thatPlate Queue field contains plate documents for all plates you intend to run.• To add a plate document to the plate queue, see “Adding Plates to thePlate Queue” on page 4-40.• To remove a plate document from the plate queue, see “Removing PlateDocuments from the Plate Queue” on page 4-40.Plate Queue(must contain platedocuments for allplates to be run)6. Prepare <strong>and</strong> load the plates onto the Plate H<strong>and</strong>ler as explained on page 4-41.<strong>Applied</strong> <strong>Biosystems</strong> <strong>7900HT</strong> <strong>Fast</strong> <strong>Real</strong>-<strong>Time</strong> <strong>PCR</strong> <strong>System</strong> <strong>and</strong> <strong>SDS</strong> Enterprise Database User Guide 4-39DRAFTSeptember 1, 2004 11:39 am, CH_Basic.fm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!