<strong>7900HT</strong> InstrumentInterchangeableThermal CyclerBlocksThe <strong>7900HT</strong> instrument features a Peltier-based, interchangeable sample blockmodule based on the technology established in the GeneAmp ® <strong>PCR</strong> <strong>System</strong> 9700thermal cycler. The sample block module houses an internal Peltier heating/coolingunit (Figure 1-4). The sample block module is made of aluminum to provide anoptimal thermal transfer rate between the block <strong>and</strong> the optical plate or theTaqMan ® Low Density Array.PHYSICAL INJURY HAZARD. Hot Surface. Use care whenworking around this area to avoid being burned by hot components.Connection to the instrument(Do Not Touch)WarningGR2027Circuitry(Do Not Touch)GR2028GR2028Block insideinstrumentSample block(Do Not Touch)Top viewHeat sinks(Do Not Touch)Bottom viewFigure 1-4Components of the Interchangeable Thermal Cycler BlockThe interchangeable sample block module provides:• Wide temperature range: 4–99.9 °C• Accuracy: ±0.25 °C from 35–99.9 °C• Heat/cool rate: 1.5 °C per second• Temperature uniformity: ±0.5 °C (measured 30 sec after the clock starts)• Long-term stability <strong>and</strong> high reliability• Support for multiple consumable formats (see page 1-9)• Several different modes of operation including 9600 mode <strong>and</strong> programmabletemperature ramps (see page 3-21)• Reduced instrument downtime by allowing immediate replacement of the block(see page 7-6)• Easy access to the sample block for troubleshooting <strong>and</strong> maintenance(see page 7-6)Optics <strong>System</strong>IMPORTANT! Do not remove the cover to the <strong>7900HT</strong> instrument. Only a qualified<strong>Applied</strong> <strong>Biosystems</strong> service engineer may repair or adjust the internal components.<strong>Applied</strong> <strong>Biosystems</strong> <strong>7900HT</strong> <strong>Fast</strong> <strong>Real</strong>-<strong>Time</strong> <strong>PCR</strong> <strong>System</strong> <strong>and</strong> <strong>SDS</strong> Enterprise Database User Guide 1-5DRAFTSeptember 1, 2004 11:38 am, CH_Overview.fm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!