11.07.2015 Views

Applied Biosystems 7900HT Fast Real-Time PCR System and SDS ...

Applied Biosystems 7900HT Fast Real-Time PCR System and SDS ...

Applied Biosystems 7900HT Fast Real-Time PCR System and SDS ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Step 1 – Creating a Plate DocumentStep 1 – Creating a Plate DocumentUser AccessRequirementAbout ABI PRISMPlate DocumentsCreating a PlateDocumentIf using the <strong>SDS</strong> Enterprise Database, you must belong to the Scientist orAdministrator User Group to create plate documents.Every plate run on the <strong>7900HT</strong> instrument requires the creation of a plate documentwithin the <strong>SDS</strong> software. Each plate document is a virtual representation of aspecific consumable (that is, a reaction plate or Low Density Array) containingsamples <strong>and</strong> reagents for use on the <strong>7900HT</strong> instrument.Plate documents contain the following information:• Detector information <strong>and</strong> arrangement on the plate• Marker information <strong>and</strong> arrangement on the plate (allelic discrimination only)• Sample information <strong>and</strong> arrangement on the plate• Method parameters for the run (absolute <strong>and</strong> relative quantification)1. If not already open, start the <strong>SDS</strong> software as explained on page 3-8.2. Click (or select File > New).3. Configure the New Document dialog box with settings for the run:• Assay drop-down list – Select the type of assay appropriate for your plate.• Container drop-down list – Select the type of consumable you intend to run.• Template drop-down list – Select Blank Template.• Barcode field – Do one of the following:If you are creating a:– Plate document to run a single plate, scan or enter the bar code for the plate.– Plate Document Template for creating multiple plates, leave the fieldblank.IMPORTANT! The <strong>SDS</strong> Enterprise Database does not support the creation oftwo plate documents of different run types with the same bar code.Note: If performing a dissociation curve experiment, select AbsoluteQuantification from the Assay drop-down list.Assay drop-down listContainer drop-down listTemplate drop-down listBarcode field4. Click .<strong>Applied</strong> <strong>Biosystems</strong> <strong>7900HT</strong> <strong>Fast</strong> <strong>Real</strong>-<strong>Time</strong> <strong>PCR</strong> <strong>System</strong> <strong>and</strong> <strong>SDS</strong> Enterprise Database User Guide 3-9DRAFTSeptember 1, 2004 11:39 am, CH_Run.fm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!