11.07.2015 Views

Applied Biosystems 7900HT Fast Real-Time PCR System and SDS ...

Applied Biosystems 7900HT Fast Real-Time PCR System and SDS ...

Applied Biosystems 7900HT Fast Real-Time PCR System and SDS ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Appendix ASoftware ReferenceSetup Table FilesAbout the SetupTable File FormatFormat OverviewConventionsThe <strong>SDS</strong> software features the ability to import setup table information into a platedocument from a tab-delimited text file. To guarantee a successful importation ofsetup table data, the imported file must follow the setup table format outlined in thissection.The information in the setup table file must be ordered according to the followingconvention:1. File Version (see page A-5)Plate Characteristics2. Plate Size (see page A-5)3. Plate ID (see page A-5)Detector Definitions4. Number of Detectors (see page A-6)5. Detectors List Header (see page A-6)6. Detectors List (see page A-7)Marker Definitions7. Number of Markers (Allelic Discrimination Only) (see page A-8)8. Markers List Header (Allelic Discrimination Only) (see page A-8)9. Markers List (Allelic Discrimination Only) (see page A-9)Well-Detector Information10. Well-Detector List Header (see page A-10)11. Well-Detector Definition List (see page A-10)Well-Marker Information12. Well-Marker List Header (Allelic Discrimination Only) (see page A-12)13. Well-Marker Definition List (Allelic Discrimination Only) (see page A-12)The following conventions are used in the rest of this section:• courier – Text appearing in bolded courier font must be applied to a setuptable file exactly as appears in this document.• italic – Text appearing in italic courier font must be substituted with customvalues when applied to a setup table file.• [ required text ] – Text appearing between brackets is requiredinformation in setup table files. All information inside the brackets must bepresent in the setup table file for the <strong>SDS</strong> software to import it.• { optional text } – Text appearing between braces is optional in setuptable files.• – The tab character (the equivalent of pressing the Tab key)• – The carriage-return character (the equivalent of pressing the Enter key)IMPORTANT! To guarantee a successful importation of the setup table file into aplate document, the file must contain all the elements described in the followingsection <strong>and</strong> in the order that they appear in this document.A-4 <strong>Applied</strong> <strong>Biosystems</strong> <strong>7900HT</strong> <strong>Fast</strong> <strong>Real</strong>-<strong>Time</strong> <strong>PCR</strong> <strong>System</strong> <strong>and</strong> <strong>SDS</strong> Enterprise Database User GuideDRAFTSeptember 1, 2004 11:39 am, App_SWReference.fm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!