11.07.2015 Views

Applied Biosystems 7900HT Fast Real-Time PCR System and SDS ...

Applied Biosystems 7900HT Fast Real-Time PCR System and SDS ...

Applied Biosystems 7900HT Fast Real-Time PCR System and SDS ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>7900HT</strong> FAST <strong>Real</strong>-<strong>Time</strong> <strong>PCR</strong> <strong>System</strong>Chapter 2Getting StartedPowering On the <strong>7900HT</strong> InstrumentPowering On theInstrumentThe activation of the <strong>Applied</strong> <strong>Biosystems</strong> <strong>7900HT</strong> <strong>Fast</strong> <strong>Real</strong>-<strong>Time</strong> <strong>PCR</strong> <strong>System</strong> issequential. You must activate each component in a specific order for the system toinitialize properly. If performed out of sequence, the components may not be able toestablish the necessary communication connections required for operation.Status lightsGR2009<strong>7900HT</strong>Front view with RobotComputerpower button<strong>7900HT</strong> instrumentpower buttonGR2009Zymark Twister MicroplateH<strong>and</strong>ler (power button in rear)Monitorpower buttonFigure 2-1 Power Buttons of the <strong>Applied</strong> <strong>Biosystems</strong> <strong>7900HT</strong> <strong>Fast</strong> <strong>Real</strong>-<strong>Time</strong><strong>PCR</strong> <strong>System</strong>IMPORTANT! Power on the power to the instrument <strong>and</strong> the Plate H<strong>and</strong>ler at least10 min before use. When activated, the instrument heats the sample block cover to105 °C. If you start a run before the heated cover reaches 105 °C, the instrument willpause until it reaches the optimal temperature before commencing the run.1. Power on the monitor <strong>and</strong> computer.2. Power on the Zymark Twister Microplate H<strong>and</strong>ler by pressing the power switchlocated on the back panel of the Plate H<strong>and</strong>ler (see below).PHYSICAL HAZARD. Keep clear of the arm whenactivating the Plate H<strong>and</strong>ler. Once activated, the arm automatically moves to itshome position.HI-POTA B C DPower switchRear Panel of the TwisterGR1728If operating normally, the Plate H<strong>and</strong>ler moves the arm to the home position(over the output stack).3. Power on the <strong>7900HT</strong> instrument by pressing the power button located belowthe status lights on the front of the instrument (see Figure 2-1).If operating normally, the <strong>7900HT</strong> instrument will do the following on startup:• Emit a high-pitched tone signaling that the instrument initialized successfully.2-4 <strong>Applied</strong> <strong>Biosystems</strong> <strong>7900HT</strong> <strong>Fast</strong> <strong>Real</strong>-<strong>Time</strong> <strong>PCR</strong> <strong>System</strong> <strong>and</strong> <strong>SDS</strong> Enterprise Database User GuideDRAFTSeptember 1, 2004 11:38 am, CH_GetStart.fm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!