11.07.2015 Views

Applied Biosystems 7900HT Fast Real-Time PCR System and SDS ...

Applied Biosystems 7900HT Fast Real-Time PCR System and SDS ...

Applied Biosystems 7900HT Fast Real-Time PCR System and SDS ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>7900HT</strong> FAST <strong>Real</strong>-<strong>Time</strong> <strong>PCR</strong> <strong>System</strong>Aligning the Plate H<strong>and</strong>lerAligning the Plate H<strong>and</strong>lerWhen to PerformPreparing theInstrument for theAlignmentPerform the following procedure if the <strong>Applied</strong> <strong>Biosystems</strong> <strong>7900HT</strong> <strong>Fast</strong> <strong>Real</strong>-<strong>Time</strong><strong>PCR</strong> <strong>System</strong> is moved or the Zymark Twister Microplate H<strong>and</strong>ler becomesmisaligned.Symptoms that the Plate H<strong>and</strong>ler is out of alignment include:• Excessive downward movement of the Plate H<strong>and</strong>ler arm (the arm grinds whengrasping or releasing plates)• The Plate H<strong>and</strong>ler arm collides with the plate stacks• The Plate H<strong>and</strong>ler arm releases plates above the bottom of the plate stacks• Reaction plates tip or tilt when placed into the instrument tray by the arm1. Remove the covers for the fixed-position bar code reader <strong>and</strong> the underlyingplatform.GR2009<strong>7900HT</strong>Front view with RobotGR2009Fixed-position bar code reader<strong>and</strong> underlying platform covers2. Loosen the three black thumbscrews on the platform connecting the <strong>7900HT</strong>instrument <strong>and</strong> the Plate H<strong>and</strong>ler base.Black thumbscrews3. Move the instrument tray to the out position.a. Start the Automation Controller Software.If an error dialog box appears reading, ‘Machine calibration values arenot valid. Please refer to documentation for calibration process,’click .b. Click .The <strong>7900HT</strong> instrument moves the instrument tray to the out position,perpendicular to the instrument.c. Select File > Exit.The software quits the Automation Controller Software.4. Select > Programs > Zymark Twister Plate H<strong>and</strong>ler > Twister.The Zymark Twister Software starts.<strong>Applied</strong> <strong>Biosystems</strong> <strong>7900HT</strong> <strong>Fast</strong> <strong>Real</strong>-<strong>Time</strong> <strong>PCR</strong> <strong>System</strong> <strong>and</strong> <strong>SDS</strong> Enterprise Database User Guide 7-41DRAFTSeptember 1, 2004 11:39 am, CH_Maintenance.fm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!