11.07.2015 Views

Applied Biosystems 7900HT Fast Real-Time PCR System and SDS ...

Applied Biosystems 7900HT Fast Real-Time PCR System and SDS ...

Applied Biosystems 7900HT Fast Real-Time PCR System and SDS ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Running Plates Using the Automation Controller SoftwareRunning Plates Using the Automation Controller SoftwareUser AccessRequirementThere is no access requirement. All users can run plates that have been saved to the<strong>SDS</strong> Enterprise Database.Loading Plates onto the Plate H<strong>and</strong>lerGuidelinesObserve the following guidelines when loading plates onto the Plate H<strong>and</strong>ler:• Before loading plates onto the Plate H<strong>and</strong>ler, make sure that for each plate:– the associated plate document has been added to the plate queue or iscontained in the <strong>SDS</strong> Enterprise Database– the plate has been sealed using an optical adhesive cover.• Load the plates into the Plate H<strong>and</strong>ler stacks in any order. The software readsthe bar code of each plate before it is run <strong>and</strong> matches the plate document <strong>and</strong>method with the plate. The Automation Controller Software can run batches ofup to 84 plates in a single session (21 plates/stack).• Orient the plates inside the stacks so that well A1 ( ) of each plate correspondsto the locations shown in Figure 4-11.• Do not place plates in the output stack (X). The Plate H<strong>and</strong>ler arm uses theempty stack to store plates after it runs them.• If loading Low Density Array(s) onto the Plate H<strong>and</strong>ler:– Load no more than 20 cards per stack.– Pack stacks of cards tightly. (The Plate H<strong>and</strong>ler may fail to detect amisaligned card correctly when loading it.)X1423Zymark Twister MicroplateH<strong>and</strong>ler (top view)Bar codeWell A1Figure 4-11Plate Positions of the Zymark Twister Microplate H<strong>and</strong>ler<strong>Applied</strong> <strong>Biosystems</strong> <strong>7900HT</strong> <strong>Fast</strong> <strong>Real</strong>-<strong>Time</strong> <strong>PCR</strong> <strong>System</strong> <strong>and</strong> <strong>SDS</strong> Enterprise Database User Guide 4-41DRAFTSeptember 1, 2004 11:39 am, CH_Basic.fm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!