Running Plates Using the Automation Controller SoftwareRunning the InstrumentStarting thePlate QueueAfter you have loaded all plate documents into the Plate Queue or saved them the<strong>SDS</strong> Enterprise Database, <strong>and</strong> you have configured the Instrument Control options,you can start the plate queue.To begin the plate queue, click from the Plate Queue tab.The Automation Controller Software does the following:1. The Zymark Twister Microplate H<strong>and</strong>ler loads the first plate from Stack 1 <strong>and</strong>places it into plate tray for the <strong>7900HT</strong> instrument.2. The fixed-position bar code reader scans the bar code for the plate.3. The Automation Controller Software does one of the following:• If linked to the <strong>SDS</strong> Enterprise Database, the software queries the databasefor the plate document with the bar code of the associated plate. Whenfound, the software automatically downloads the plate document.If the software does not find a plate document with a matching bar code inthe database, the software searches the contents of the plate queue asexplained below.• If not linked to a database, the software searches the plate queue for theplate document with the bar code of the associated plate. If found, theAutomation Controller Software loads the plate document informationfrom the file system for the run.4. The <strong>7900HT</strong> instrument loads the instrument tray <strong>and</strong> runs the plate accordingto the parameters defined by the plate document file.Note: Before starting a real-time run, the instrument may pause (up to15 minutes) to heat the heated cover to the appropriate temperature.If using the <strong>SDS</strong> Enterprise Database, the Automation Controller Softwareautomatically conducts a primary analysis of each completed run <strong>and</strong> saves theresults to the database. If you specified a study or studies as explained in“Associating Session <strong>and</strong> Study Data” on page 4-33, then the softwareautomatically attaches the analyzed session data to the appropriate study.The following options are available during <strong>and</strong> after the completion of the run:To…See PageMonitor the progress of the run 4-44Stop the runIMPORTANT! If you must stop a run in-progress for any reason,carefully read the instructions on page 4-28 before halting the run.4-44Open the instrument tray (after the run) 4-44Analyze the run data after the run is complete 4-44<strong>Applied</strong> <strong>Biosystems</strong> <strong>7900HT</strong> <strong>Fast</strong> <strong>Real</strong>-<strong>Time</strong> <strong>PCR</strong> <strong>System</strong> <strong>and</strong> <strong>SDS</strong> Enterprise Database User Guide 4-43DRAFTSeptember 1, 2004 11:39 am, CH_Basic.fm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!