11.07.2015 Views

Applied Biosystems 7900HT Fast Real-Time PCR System and SDS ...

Applied Biosystems 7900HT Fast Real-Time PCR System and SDS ...

Applied Biosystems 7900HT Fast Real-Time PCR System and SDS ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Performing a Pure Dye Run• <strong>Fast</strong> 96-Well Pure Dye Run: select the plate document template matchingthe Pure Dye plate you intend to run.To run Plate 1 (containing FAM, JOE, NED, <strong>and</strong> ROX dyes), select<strong>Fast</strong> 96 Well Pure Dyes Plate 1.sdt.To run Plate 2 (containing SYBR, TAMRA, TET, <strong>and</strong> VIC dyes), select<strong>Fast</strong> 96 Well Pure Dyes Plate 2.sdt.• Microfluidic Pure Dye Run: leave the field blank.To run the microfluidic pure dye card containing FAM dye,select MFC FAM Pure Dyes.sdt.To run the microfluidic pure dye card containing ROX dye,select MFC ROX Pure Dyes.sdt.To run the microfluidic pure dye card containing VIC dye,select MFC VIC Pure Dyes.sdt.4. In the Barcode field, scan the bar code number using the h<strong>and</strong>-held bar codereader.5. Click . The software displays a plate document with the attributes for apure dye run.6. Save the Pure Dye plate document:a. Click (or select File > Save).b. Select Files of type > <strong>SDS</strong> <strong>7900HT</strong> Document (*.sds).c. In the File name field, if running a:• St<strong>and</strong>ard 384-Well Plate, enter PureDye_For example, the file name for a plate run on May 31, 2001 would be:PureDye_053101.• St<strong>and</strong>ard 96-Well Plate, enter PureDye_Plate_For example, the file name for a Pure Dye Plate 1 run on May 31, 2001would be: PureDye_Plate1_053101.• <strong>Fast</strong> 96-Well Plate, enter <strong>Fast</strong>PureDye_Plate_.sdsFor example, for a fast pure dye plate 1 run on May 31, 2001, type:<strong>Fast</strong>PureDye_Plate1_053101.sds• Microfluidic pure dye card, enter _MFCFor example, the file name for a run performed on May 31, 2001 would be:FAM_053101_MFC.d. Click .The software saves the plate document.7. Prepare <strong>and</strong> run the pure dye plate or card as explained below.<strong>Applied</strong> <strong>Biosystems</strong> <strong>7900HT</strong> <strong>Fast</strong> <strong>Real</strong>-<strong>Time</strong> <strong>PCR</strong> <strong>System</strong> <strong>and</strong> <strong>SDS</strong> Enterprise Database User Guide 7-23DRAFTSeptember 1, 2004 11:39 am, CH_Maintenance.fm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!