Compatible ConsumablesCompatible ConsumablesConsumables forUse with the<strong>7900HT</strong>InstrumentThe interchangeable sample block modules of the <strong>7900HT</strong> instrument allow it tosupport a variety of consumable formats listed in Table 1-1.Table 1-1Compatible ConsumablesConsumableABI PRISM 384-Well OpticalReaction PlatesABI PRISM 96-Well OpticalReaction PlatesOptical 96-Well <strong>Fast</strong> ThermalCycling PlatesTaqMan ® Low Density ArraysCompatible Seals• ABI PRISM Optical Adhesive Covers(quantity 100)• Optical Adhesive Covers (quantity 25)• Compression Pads:– St<strong>and</strong>ard pad for manual operation– ABI PRISM Snap-On Compression Pad(reusable)• 96-Well Plate Seals:– ABI PRISM Optical Adhesive Covers(quantity 100)– Optical Adhesive Covers (quantity 25)– ABI PRISM Optical Caps (flat caps only)• ABI PRISM Optical Adhesive Covers(quantity 100)• Optical Adhesive Covers (quantity 25)None (self sealing)CompressionPads for theABI PRISM96-Well OpticalReaction PlatesConsumableRequirementsTo ensure optimal heat transfer, <strong>Applied</strong> <strong>Biosystems</strong> recommends using compressionpads when running the ABI PRISM 96-Well Optical Reaction Plates.If you are going to run the plate:• Individually using the <strong>SDS</strong> software, then apply a st<strong>and</strong>ard compression pad• As part of a batch using the Automation Controller Software, then apply anABI PRISM Snap-On Compression PadIMPORTANT! The ABI PRISM Snap-On Compression Pad/plate assembly may stillbe hot after the Zymark ® Twister Microplate H<strong>and</strong>ler loads it into the Plate H<strong>and</strong>ler’soutput stack. Please wait at least 30 seconds before manually h<strong>and</strong>ling the Snap-OnCompression Pad/plate assembly.IMPORTANT! Performance of the Optical 96-Well <strong>Fast</strong> Thermal Cycling Plates withthe Zymark Twister Microplate H<strong>and</strong>ler has not been verified. Therefore, whenrunning multiple Optical 96-Well <strong>Fast</strong> Plates on the <strong>7900HT</strong> instrument, <strong>Applied</strong><strong>Biosystems</strong> recommends that you load <strong>and</strong> unload the plates manually.See Appendix C, “Kits, Reagents, <strong>and</strong> Consumables,” for a list of availableconsumables, requirements, <strong>and</strong> purchasing instructions.<strong>Applied</strong> <strong>Biosystems</strong> <strong>7900HT</strong> <strong>Fast</strong> <strong>Real</strong>-<strong>Time</strong> <strong>PCR</strong> <strong>System</strong> <strong>and</strong> <strong>SDS</strong> Enterprise Database User Guide 1-9DRAFTSeptember 1, 2004 11:38 am, CH_Overview.fm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!