Chapter 7Maintaining the InstrumentRunning theVerification Plateor TGF-β CardVerifyingInstrumentPerformance1. In the plate document in the <strong>SDS</strong> software, select the Instrument tab.2. In the lower portion of the Instrument tab, select the <strong>Real</strong>-<strong>Time</strong> tab.3. If the instrument tray is inside the <strong>7900HT</strong> instrument, click .The instrument tray rotates to the OUT position.4. Place the TaqMan RNase P Instrument Verification Plate or TGF-β card into theinstrument tray.Note: The A1 position is located in the top-left corner of the instrument tray.5. In the <strong>Real</strong>-<strong>Time</strong> tab, click . The <strong>7900HT</strong> instrument begins the run.Note: Before starting the <strong>PCR</strong> run, the instrument may pause (up to 15 min) toheat the heated cover to the appropriate temperature.6. When the run is complete:a. Analyze the run data as explained on page 6-12.b. Set the baseline <strong>and</strong> threshold values for the analyzed data as explained onpage 6-46.c. Verify the performance of the <strong>7900HT</strong> instrument as explained below.Analyzing Data from RNase P RunsThe install specification of the <strong>Applied</strong> <strong>Biosystems</strong> <strong>7900HT</strong> <strong>Fast</strong> <strong>Real</strong>-<strong>Time</strong> <strong>PCR</strong><strong>System</strong> demonstrates the ability to distinguish between 5,000 <strong>and</strong> 10,000 genomeequivalents with a 99.7% confidence level for a subsequent sample run in a singlewell.The following equation verifies the <strong>7900HT</strong> instrument install specifications:[( CopyUnk 1)–3( σ CopyUnk1)] > [( CopyUnk 2)–3( σ CopyUnk2)]where:• CopyUnk 1 is the Average Copy Number of Unknown #1 (10,000 replicatepopulation)• σ CopyUnk1 is the St<strong>and</strong>ard Deviation of Unknown #1 (10,000 replicate population)• CopyUnk 2 is the Average Copy Number of Unknown #2 (5000 replicatepopulation)• σ CopyUnk2 is the St<strong>and</strong>ard Deviation of Unknown #2 (5000 replicate population)Note: The values above can be obtained from the experimental report window.Note: Up to six wells from each replicate group in a 96-well TaqMan RNase PInstrument Verification Plate (both st<strong>and</strong>ard 96-well <strong>and</strong> <strong>Fast</strong> 96-well plates) can beignored to meet specifications.Note: Up to 10 wells from each replicate group in a 384-well TaqMan RNase PInstrument Verification Plate can be ignored to meet specifications.7-34 <strong>Applied</strong> <strong>Biosystems</strong> <strong>7900HT</strong> <strong>Fast</strong> <strong>Real</strong>-<strong>Time</strong> <strong>PCR</strong> <strong>System</strong> <strong>and</strong> <strong>SDS</strong> Enterprise Database User GuideDRAFTSeptember 1, 2004 11:39 am, CH_Maintenance.fm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!