Appendix CKits, Reagents, <strong>and</strong> ConsumablesInterchangeable Sample Block Modules <strong>and</strong> AccessoriesThe <strong>7900HT</strong> instrument features a Peltier-based, interchangeable sample block modulebased on the technology established in the GeneAmp ® <strong>PCR</strong> <strong>System</strong> 9700 thermal cycler.The use of an interchangeable sample block module:• Reduces instrument downtime by allowing immediate replacement of the block.• Permits easy access to the sample block for troubleshooting <strong>and</strong> maintenance(see page 7-14).• Supports multiple consumable formats.• Provides several different modes of operation (including Max mode <strong>and</strong>programmable temperature ramps).Table C-1Sample Block Modules <strong>and</strong> AccessoriesPart No. Description Quantity4331406 <strong>7900HT</strong> <strong>System</strong> St<strong>and</strong>ard 384-Well Block Upgrade KitIncludes a St<strong>and</strong>ard 384-Well Block, a 384-well plate adapter,<strong>and</strong> a Sequence Detection <strong>System</strong>s 384-Well SpectralCalibration Kit (PN 4323977)4331405 <strong>7900HT</strong> <strong>System</strong> St<strong>and</strong>ard 96-Well Block Upgrade KitIncludes a St<strong>and</strong>ard 96-Well Block, a 96-well plate adapter,<strong>and</strong> an ABI PRISM <strong>7900HT</strong> Sequence Detection <strong>System</strong>s96-Well Spectral Calibration Kit (PN 4328639)4351402 <strong>7900HT</strong> <strong>System</strong> <strong>Fast</strong> 96-Well Block Upgrade KitIncludes a <strong>Fast</strong> 96-Well Block, a <strong>Fast</strong> 96-Well Plate Adapter, a<strong>7900HT</strong> <strong>System</strong> <strong>Fast</strong> 96-Well Spectral Calibration Kit(PN 4351653), a TaqMan ® RNase P <strong>Fast</strong> 96-Well InstrumentVerification Plate (PN 4351979), <strong>and</strong> a TaqMan ® <strong>Fast</strong>Reagents Starter Kit (PN 4352407)1kit1kit1kit4329012 <strong>7900HT</strong> <strong>System</strong> TaqMan ® Low Density Array Upgrade 1 kitC-2 <strong>Applied</strong> <strong>Biosystems</strong> <strong>7900HT</strong> <strong>Fast</strong> <strong>Real</strong>-<strong>Time</strong> <strong>PCR</strong> <strong>System</strong> <strong>and</strong> <strong>SDS</strong> Enterprise Database User GuideDRAFTSeptember 1, 2004 11:39 am, App_Consumables.fm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!