SECTION 2.10<br />

ABOVEGROUND TRAINWAYS<br />

2.10.1 CONSTRUCTION MATERIALS<br />

2.10.1.1 Aboveground tra<strong>in</strong>ways shall be constructed of noncombustible<br />

materials.<br />

2.10.1.2 The elements of structure <strong>for</strong> aboveground tra<strong>in</strong>ways shall<br />

have a fire resistance of not less than 2 hours.<br />

2.10.1.3 Test of fire resistance shall be <strong>in</strong> accordance with Cl.2.3.4.<br />

2.10.1.4 Coverboard or any protective material used to provide safety<br />

isolation from the contact traction power rail shall have a<br />

flame spread rat<strong>in</strong>g of not less than Class 1 as specified <strong>in</strong><br />

Cl.2.3.13.3 when tested <strong>in</strong> accordance with BS 476: Part 7.<br />

2.10.2 SETBACK DISTANCE<br />

2.10.2.1 Setback distance between tra<strong>in</strong>way structure and adjacent<br />

build<strong>in</strong>g<br />

(a) The setback distance between the proposed tra<strong>in</strong>way<br />

structure and the adjacent build<strong>in</strong>g shall comply with<br />

the distance stipulated <strong>in</strong> Appendix D based on the<br />

extent of unprotected open<strong>in</strong>gs <strong>in</strong> the external wall of<br />

the adjacent build<strong>in</strong>g, us<strong>in</strong>g the outermost edge of the<br />

proposed tra<strong>in</strong>way structure as the relevant boundary,<br />

or at least 6m clear of the outermost edge of the<br />

proposed tra<strong>in</strong>way structure, whichever is greater<br />

(Diagram 2.10.2.1(a)).<br />

(b) For proposed tra<strong>in</strong>way located outside the development<br />

boundary of a private development, the distance<br />

between the adjacent build<strong>in</strong>g(s) and the outermost<br />

edge of the proposed tra<strong>in</strong>way shall be at least 6m<br />

(Diagram 2.10.2.1(b)).<br />

2.10.2.2 The setback distance shall be measured from the edge of<br />

tra<strong>in</strong>ways to the external wall of the adjacent build<strong>in</strong>gs.<br />

2.10.2.3 The height of the enclos<strong>in</strong>g rectangle used <strong>in</strong> the calculations<br />

shall be measured up to the height of the tra<strong>in</strong>ways.<br />

Construction<br />

materials<br />

Setback<br />

distance<br />

<strong>Standard</strong> <strong>for</strong> <strong>Fire</strong> <strong>Safety</strong> <strong>in</strong> <strong>Rapid</strong> <strong>Transit</strong> <strong>Systems</strong> 149