(h) 850mm <strong>for</strong> doors and gates, and<br />

(i) 500mm <strong>for</strong> underplat<strong>for</strong>m services ducts.<br />

2.2.5.5 The maximum length of dead-end shall not exceed 15m<br />

(non-spr<strong>in</strong>klered) or 20m (spr<strong>in</strong>klered).<br />

2.2.5.6 EXIT STAIRCASE<br />

Dead-end<br />

(a) Internal Exit Staircase Internal exit<br />

staircase<br />

(i) Except as permitted <strong>in</strong> Cl.2.2.3.2 an <strong>in</strong>ternal<br />

exit staircase which serves as the required exit<br />

of the station shall be enclosed with<br />

construction comply<strong>in</strong>g with the provisions of<br />

Cl.2.3.8, and<br />

(ii) Where an <strong>in</strong>ternal exit staircase is directly<br />

approached from an external exit passageway or<br />

external corridor, it shall not be necessary to<br />

provide such enclosure between the staircase<br />

and the external exit passageway or external<br />

corridor provided no unprotected open<strong>in</strong>gs are<br />

located with<strong>in</strong> 3m from the exit staircase, and<br />

(iii) There shall be no unprotected open<strong>in</strong>gs of<br />

occupancy area with<strong>in</strong> 1.5m horizontally or<br />

with<strong>in</strong> 3m vertically below any part of the<br />

ventilation open<strong>in</strong>gs located <strong>in</strong> the external wall<br />

of the <strong>in</strong>ternal exit staircase.<br />

(b) External Exit Staircase External exit<br />

staircase<br />

(i) External exit staircase may be used as required<br />

exit <strong>in</strong> lieu of <strong>in</strong>ternal exit staircase provided it<br />

complies with the requirements of exit staircase,<br />

except <strong>for</strong> enclosure of an <strong>in</strong>ternal staircase, and<br />

(ii) There shall be no unprotected open<strong>in</strong>gs with<strong>in</strong> 3<br />

m horizontally or with<strong>in</strong> 3m vertically below<br />

any part of the external exit staircase.<br />

(c) All exit staircases shall discharge at ground level<br />

directly <strong>in</strong>to a safe exterior open space.<br />

(d) The m<strong>in</strong>imum width and capacity of exit staircases<br />

shall be <strong>in</strong> accordance with Cl.2.2.3.7, Cl.2.2.4.6 and<br />

Cl.2.2.5.4.<br />

Discharge<br />