- Page 1 and 2:
Standard for Fire Safety in Rapid T
- Page 3 and 4:
2.3.13 Restriction of Spread of fla
- Page 5 and 6:
SECTION 3.2 - OCC and RTS Facility
- Page 7 and 8:
1.1.4 ABBREVIATIONS The abbreviatio
- Page 9 and 10:
2.1.2.5 Area of Refuge (a) In the s
- Page 11 and 12:
2.1.2.16 A space enclosed by elemen
- Page 13 and 14:
2.1.2.27 A means of egress from the
- Page 15 and 16:
2.1.2.45 The height of station or (
- Page 17 and 18:
2.1.2.64 An enclosed space that is
- Page 19 and 20:
2.1.3 STATION OCCUPANCY 2.1.3.1 The
- Page 21 and 22:
CODE Table 2.1.3 APPROVED TRADES AN
- Page 23 and 24:
SECTION 2.2 STATION MEANS OF ESCAPE
- Page 25 and 26:
2.2.3 MEANS OF ESCAPE FROM PLATFORM
- Page 27 and 28:
2.2.3.9 Gate-type emergency exits s
- Page 29 and 30:
2.2.4.7 The maximum travel distance
- Page 31 and 32:
(iii) Permanently fixed ventilation
- Page 33 and 34:
(h) 850mm for doors and gates, and
- Page 35 and 36:
300 mm (iii) The sign shall be loca
- Page 37 and 38:
(d) Exit ramps shall be straight wi
- Page 39 and 40:
(d) Ventilation 2.2.5.12 ESCALATORS
- Page 41 and 42:
(ii) All exit access doors which op
- Page 43 and 44:
2.2.5.14 FARE COLLECTION GATES AND
- Page 45 and 46:
2.2.5.19 Photo luminescent marking
- Page 47 and 48:
Diagram 2.2.4.4 - Means of escape f
- Page 49 and 50:
Diagram 2.2.5.13(e) - Exit doors sh
- Page 51 and 52:
Diagram 2.2.5.16(a)(v) - Remoteness
- Page 53 and 54:
SECTION 2.3 STATION STRUCTURAL FIRE
- Page 55 and 56:
2.3.1 GENERAL SECTION 2.3 STATION S
- Page 57 and 58:
(c) Commercial spaces shall be comp
- Page 59 and 60:
(h) Coldroom Where the enclosure to
- Page 61 and 62:
(b) Any reference to height means t
- Page 63 and 64:
2.3.5 EXTERNAL WALL 2.3.5.1 Externa
- Page 65 and 66:
2.3.6.2 A separating wall shall hav
- Page 67 and 68:
(b) Have the appropriate fire resis
- Page 69 and 70:
2.3.8.8 A protected shaft which con
- Page 71 and 72:
(ii) Drywall shall have the requisi
- Page 73 and 74:
2.3.9.3 Pipes (a) Pipes which pass
- Page 75 and 76:
2.3.10.3 Doors opening into the exi
- Page 77 and 78:
(h) All sides shall be properly sea
- Page 79 and 80:
(v) Intumescent mastics. The method
- Page 81 and 82:
(e) Cl.2.3.8.2(c), 2.3.8.4, 2.3.8.7
- Page 83 and 84:
Table 2.3.2A SIZE LIMITATION OF STA
- Page 85 and 86:
Table 2.3.9A MAXIMUM NOMINAL INTERN
- Page 87 and 88:
Diagram 2.3.3.1(c) - Fire resistanc
- Page 89 and 90:
2.4.1 GENERAL SECTION 2.4 SITE PLAN
- Page 91 and 92:
ii) For stations not exceeding the
- Page 93 and 94:
2.4.4 PRIVATE FIRE HYDRANT 2.4.4.1
- Page 95 and 96:
(c) Where there are more than one p
- Page 97 and 98:
Diagram 2.4.2.4(b)(vi) U-Turn Radii
- Page 99 and 100:
Diagram 2.4.4.1(b) - Provision of P
- Page 101 and 102:
S2.5.3 Fire protection systems to c
- Page 103 and 104:
2.5.2.5 Portable fire extinguishers
- Page 105 and 106:
2.5.3.5 The dry mains’ breeching
- Page 107 and 108:
2.5.5.2 The fire alarm system shall
- Page 109 and 110: 2.5.6 SPRINKLER INSTALLATION 2.5.6.
- Page 111 and 112: 2.5.7 LIFTS 2.5.7.1 Lifts (includin
- Page 113 and 114: SECTION 2.6 STATION SMOKE CONTROL A
- Page 115 and 116: 2.6.1 GENERAL SECTION 2.6 STATION S
- Page 117 and 118: (e) Where the supply air duct servi
- Page 119 and 120: (c) The smoke purging system design
- Page 121 and 122: 2.6.5.2 The design shall encompass
- Page 123 and 124: Diagram 2.6.1.4(a) - Fresh/exhaust
- Page 125 and 126: S2.7.2 Provisions for adequate and
- Page 127 and 128: (b) Notwithstanding the requirement
- Page 129 and 130: (g) Exit signs in metal enclosures
- Page 131 and 132: 2.7.2.10 PA systems for stations wi
- Page 133 and 134: (c) Supply air shall be drawn direc
- Page 135 and 136: 2.8.1 GENERAL SECTION 2.8 INTEGRATI
- Page 137 and 138: 2.8.4.2 Where a station has an unde
- Page 139 and 140: SECTION 2.9 UNDERGROUND OR ENCLOSED
- Page 141 and 142: S2.9.10 Provisions for ventilation
- Page 143 and 144: 2.9.2.3 Where underground or enclos
- Page 145 and 146: 2.9.3.5 The emergency lighting shal
- Page 147 and 148: 2.9.6.3 An engineering analysis is
- Page 149 and 150: 2.9.8 MOTORISED TROLLEY 2.9.8.1 Mot
- Page 151 and 152: Diagram 2.9.4.2 - Numbering and lab
- Page 153 and 154: ROOT OBJECTIVES SECTION 2.10 ABOVEG
- Page 155 and 156: 2.10.3 EMERGENCY ACCESS 2.10.3.1 Em
- Page 157 and 158: PART III - RTS DEPOT AND RELATED FA
- Page 159: (g) The maximum travel distance for
- Page 163 and 164: For RTS Facility Buildings S3.2.5 P
- Page 165 and 166: PART IV - ELECTRICAL SYSTEM FOR RAP
- Page 167 and 168: 4.1.3.2 Not withstanding the above,
- Page 169 and 170: APPENDIX A OCCUPANT LOAD CALCULATIO
- Page 171 and 172: A.2.3 For a single service centre p
- Page 173 and 174: A.3.3 For a multi-service centre pl
- Page 175 and 176: 1 2 3 4 5 APPENDIX A, TABLE A : SIN
- Page 177 and 178: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
- Page 179 and 180: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
- Page 181 and 182: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
- Page 183 and 184: Number of People APPENDIX A, FIGURE
- Page 185 and 186: B.1 GENERAL APPENDIX B EXITING ANAL
- Page 187 and 188: any enclosing structure for Escape
- Page 189 and 190: TEST #2 FOR ESCAPE ROUTE 2 TOTAL WA
- Page 191 and 192: A. Masonry construction - continued
- Page 193 and 194: APPENDIX C - continued PART II : RE
- Page 195 and 196: 1. Dense concrete: APPENDIX C - con
- Page 197 and 198: APPENDIX C - continued PART V : STR
- Page 199 and 200: APPENDIX C - continued PART VIII :
- Page 201 and 202: Width of enclosing rectangle in met
- Page 203 and 204: Width of enclosing rectangle in met
- Page 205 and 206: Width of enclosing rectangle in met
- Page 207 and 208: Width of enclosing rectangle in met
- Page 209 and 210: Width of enclosing rectangle in met
- Page 211 and 212:
APPENDIX E ACCESSWAY E.1 In general
- Page 213 and 214:
APPENDIX F STANDBY FIRE HOSE FOR RI
- Page 215 and 216:
G.1 General APPENDIX G TENABLE ENVI
- Page 217 and 218:
where: tIconv = time in minutes T =
- Page 219 and 220:
APPENDIX H NOTES ON THE USE OF INTU
- Page 221 and 222:
APPENDIX J FIRE SAFETY REQUIREMENTS
- Page 223 and 224:
J.5.3 In the event of fire emergenc