(d) Ventilation<br />
2.2.5.12 ESCALATORS<br />
(i) Except as permitted by sub-clause (ii), all<br />
<strong>in</strong>ternal exit passageways shall be naturally<br />
ventilated by fixed ventilation open<strong>in</strong>gs <strong>in</strong> an<br />
external wall, such ventilation open<strong>in</strong>gs be<strong>in</strong>g<br />
not less than 15 per cent of the floor area of the<br />
exit passageway, and<br />
(ii) Internal exit passageways that cannot be<br />
naturally ventilated shall be mechanically<br />
ventilated to comply with the requirements <strong>in</strong><br />
Section 2.6.<br />
(a) Escalators not fire-separated from the public floor<br />
area shall be considered as contribut<strong>in</strong>g to the means<br />
of escape capacity.<br />
(b) Escalators shall not account <strong>for</strong> more than 50% of the<br />
exit capacity at any one level.<br />
(c) Because of the possibilities of ma<strong>in</strong>tenance or<br />
malfunction, one escalator at each station shall be<br />
considered as be<strong>in</strong>g out of service <strong>in</strong> calculat<strong>in</strong>g<br />
egress requirements. The escalators chosen shall be<br />
the one hav<strong>in</strong>g the most adverse effect upon exit<strong>in</strong>g<br />
capacities.<br />
(d) The width of the escalator shall be the width of the<br />
step tread.<br />
(e) Escalators shall be provided with flat steps at<br />
land<strong>in</strong>gs which <strong>in</strong>crease <strong>in</strong> number proportionally<br />
with the rise of the escalator as follows:<br />
Rise Number of Flat Steps<br />
Up to 6 m Not less than 2<br />
6 – 18 m Not less than 3<br />
Over 18 m Not less than 4<br />
(f) Where operat<strong>in</strong>g <strong>in</strong> the direction of exit travel,<br />
escalators shall be permitted to be left <strong>in</strong> the<br />
operat<strong>in</strong>g mode dur<strong>in</strong>g evacuation.<br />
Ventilation<br />
Escalators<br />
<strong>Standard</strong> <strong>for</strong> <strong>Fire</strong> <strong>Safety</strong> <strong>in</strong> <strong>Rapid</strong> <strong>Transit</strong> <strong>Systems</strong> 34