(e) No part along the direction of escape shall be less<br />

than the m<strong>in</strong>imum required width <strong>for</strong> the stairs and<br />

land<strong>in</strong>gs.<br />

(f) Handrails<br />

(i) Every exit staircase shall have handrails on both<br />

sides, except that staircases that are 1250mm or<br />

less <strong>in</strong> width may have a handrail on one side<br />

only, and<br />

Exception: Handrails are not required <strong>for</strong> any<br />

staircase hav<strong>in</strong>g not more than 5 risers.<br />

(ii) Where staircases exceed 2000mm <strong>in</strong> width,<br />

handrails shall be used to divide the staircase<br />

<strong>in</strong>to sections of not less than 1000mm of width<br />

or more than 2000mm of width, and<br />

(iii) Handrail ends shall be returned to the wall or<br />

floor or shall term<strong>in</strong>ate at newel posts, and<br />

(iv) Handrails that are not cont<strong>in</strong>uous between<br />

flights shall extend horizontally, at the required<br />

height, at least 300mm beyond the top riser and<br />

cont<strong>in</strong>ue to slope <strong>for</strong> a depth of one tread<br />

beyond the bottom riser.<br />

(g) Where fire-separated exit staircases are provided,<br />

(i) There shall be no enclosed useable space with<strong>in</strong><br />

the exit enclosure, <strong>in</strong>clud<strong>in</strong>g under stairs, and<br />

(ii) The exit enclosure shall not be used <strong>for</strong> any<br />

purpose that has the potential to <strong>in</strong>terfere with<br />

egress.<br />

(h) Staircases shall be provided with a sign not smaller<br />

than 300mm x 300mm with<strong>in</strong> the stairwell at each<br />

storey land<strong>in</strong>g. The sign shall conta<strong>in</strong> the follow<strong>in</strong>g<br />

<strong>in</strong><strong>for</strong>mation <strong>in</strong> the order as follows:<br />

(i) The storey number, at least 125mm <strong>in</strong> height<br />

(ii) An identification of the staircase <strong>in</strong> alphabet<br />

and/or number, at least 25mm <strong>in</strong> height.<br />

Handrails<br />

No useable<br />

space <strong>in</strong> exit<br />

enclosure<br />

Stair<br />

identification<br />

sign<br />

<strong>Standard</strong> <strong>for</strong> <strong>Fire</strong> <strong>Safety</strong> <strong>in</strong> <strong>Rapid</strong> <strong>Transit</strong> <strong>Systems</strong> 29