(c) Where there are habitable floors directly above a<br />
tra<strong>in</strong>way with<strong>in</strong> an above-ground station, the fire<br />
resistance of elements of structure around the tra<strong>in</strong>way<br />
with<strong>in</strong> the station shall be not less than 4 hours as<br />
shown Diagram 2.3.3.1(c).<br />
2.3.3.2 Noth<strong>in</strong>g <strong>in</strong> Cl.2.3.3.1 shall apply to any part of any external<br />
wall which is non-loadbear<strong>in</strong>g and may, <strong>in</strong> accordance with<br />
Cl.2.3.5 be an unprotected area.<br />
2.3.3.3 In the case of a station consist<strong>in</strong>g of a first storey and one or<br />
more basement storeys, noth<strong>in</strong>g <strong>in</strong> Cl. 2.3.3.1 shall apply to<br />
any element of structure which <strong>for</strong>ms part of the first storey<br />
and consists of:<br />
(a) A structural frame or a beam or column, provided that<br />
any beam or column (whether or not it <strong>for</strong>ms part of a<br />
structural frame) which is with<strong>in</strong> or <strong>for</strong>ms part of a<br />
wall, and any column which gives support to a wall or<br />
gallery, shall have fire resistance of not less than the<br />
m<strong>in</strong>imum period, if any, required by this standard <strong>for</strong><br />
that wall or gallery, or<br />
(b) An <strong>in</strong>ternal loadbear<strong>in</strong>g wall or a loadbear<strong>in</strong>g part of a<br />
wall, unless that wall or part is, or <strong>for</strong>ms, part of a<br />
compartment wall or a separat<strong>in</strong>g wall, or <strong>for</strong>ms part of<br />
the structure enclos<strong>in</strong>g a protected shaft or supports a<br />
gallery, or<br />
(c) Part of an external wall which does not support a<br />
gallery and which may, <strong>in</strong> accordance with Cl.2.3.5 be<br />
an unprotected area.<br />
2.3.3.4 The <strong>in</strong>terpretation and application of Cl.2.3.3 shall be as<br />
follows:<br />
(a) Subject to the provisions of sub-cl. (b) and any other<br />
expressed provision to the contrary, any reference to a<br />
station of which an element of structure <strong>for</strong>ms a part<br />
means the station or (if the station is divided <strong>in</strong>to<br />
compartments) any compartment of the station of<br />
which the element <strong>for</strong>ms a part, and<br />
Exemption <strong>for</strong><br />
nonloadbear<strong>in</strong>g<br />
external walls<br />
Exemption <strong>for</strong><br />
s<strong>in</strong>gle storey<br />
structure<br />
Interpretation<br />
and<br />
application of<br />
Cl. 2.3.3<br />
<strong>Standard</strong> <strong>for</strong> <strong>Fire</strong> <strong>Safety</strong> <strong>in</strong> <strong>Rapid</strong> <strong>Transit</strong> <strong>Systems</strong> 55