APPENDIX C - cont<strong>in</strong>ued<br />
PART V : STRUCTURAL STEEL<br />
A. Encased steel stanchions (Mass per metre not less than 45 Kg)<br />
A. SOLID PROTECTION *<br />
(unplastered)<br />
Construction and materials<br />
1. Concrete not leaner than 1:2:4 mix with natural aggregates-<br />
(a) concrete not assumed to be load-bear<strong>in</strong>g re<strong>in</strong><strong>for</strong>ced +<br />
(b) concrete assumed to be load-bear<strong>in</strong>g, re<strong>in</strong><strong>for</strong>ced <strong>in</strong> accordance with BS 5950: Part 8<br />
M<strong>in</strong>imum thickness<br />
(<strong>in</strong> mm) of protection<br />
<strong>for</strong> a fire resistance of<br />
4<br />
hours<br />
2<br />
hours<br />
2. Solid bricks of clay, composition or sand-lime 100 50 50<br />
3. Solid blocks of foamed slag or pumice concrete re<strong>in</strong><strong>for</strong>ced + <strong>in</strong> every horizontal jo<strong>in</strong>t 75 50 50<br />
4. Sprayed vermiculite-cement - 38 19<br />
B. HOLLOW PROTECTION ++<br />
1. Solid bricks of clay, composition or sand-lime re<strong>in</strong><strong>for</strong>ced <strong>in</strong> every horizontal jo<strong>in</strong>t, unplastered 115 50 50<br />
2. Solid blocks of foamed slag or pumice concrete re<strong>in</strong><strong>for</strong>ced + <strong>in</strong> every horizontal jo<strong>in</strong>t, unplastered 75 50 50<br />
3. Metal lath<strong>in</strong>g with gypsum or cement-lime plaster of thickness of- - 38 § 19<br />
4. (a) Metal lath<strong>in</strong>g with vermiculite-gypsum or perlite-gypsum plaster of thickness of<br />
(b) Metal lath<strong>in</strong>g spaced 25mm from flanges with vermiculite-gypsum or perlite-gypsum<br />
plaster of thickness of<br />
5. Gypsum plasterboard with 1.6mm wire b<strong>in</strong>d<strong>in</strong>g at 100mm pitch -<br />
(a) 9.5mm Plasterboard with gypsum plaster of thickness of<br />
(b) 19mm Plasterboard with gypsum plaster of thickness of<br />
6. Gypsum plasterboard with 1.6mm wire b<strong>in</strong>d<strong>in</strong>g at 100mm pitch-<br />
(a) 9.5mm plasterboard with vermiculite-gypsum plaster of thickness of<br />
(b) 19mm plasterboard with vermiculite- gypsum plaster of thickness of<br />
7. Vermiculite - cement slabs of 4:1 mix re<strong>in</strong><strong>for</strong>ced with wire mesh and f<strong>in</strong>ished with<br />
plaster skim. Slabs of thickness of<br />
* Solid protection means a cas<strong>in</strong>g which is bedded close to the steel without <strong>in</strong>terven<strong>in</strong>g cavities and with all jo<strong>in</strong>ts <strong>in</strong> that<br />
cas<strong>in</strong>g made full and solid.<br />
+ Re<strong>in</strong><strong>for</strong>cement shall consist of steel b<strong>in</strong>d<strong>in</strong>g wire not less than 2.3mm <strong>in</strong> thickness, or a steel mesh weigh<strong>in</strong>g not less than<br />
0.48 kg/m 2 . In concrete protection, the spac<strong>in</strong>g of that re<strong>in</strong><strong>for</strong>cement shall not exceed 150mm <strong>in</strong> any direction.<br />
++ Hollow protection means that there is a void between the protective material and the steel. All hollow protection to columns<br />
shall be effectively sealed at each floor level.<br />
§ Light mesh re<strong>in</strong><strong>for</strong>cement required 12.5mm to 19mm below surface unless special corner beads are used.<br />
<strong>Standard</strong> <strong>for</strong> <strong>Fire</strong> <strong>Safety</strong> <strong>in</strong> <strong>Rapid</strong> <strong>Transit</strong> <strong>Systems</strong> C-7<br />
50<br />
75<br />
50 §<br />
44<br />
-<br />
-<br />
-<br />
38 §<br />
63<br />
25<br />
50<br />
19<br />
19<br />
-<br />
12.5<br />
16<br />
20<br />
25<br />
1<br />
hour<br />
25<br />
50<br />
12.5<br />
12.5<br />
12.5<br />
7<br />
10<br />
10<br />
25