2.2.3.6 Exit capacity shall be calculated <strong>in</strong> accordance with<br />

Cl.2.2.3.7 on the basis of the clear width of means of escape.<br />

The clear width of means of escape shall be the m<strong>in</strong>imum<br />

width required under Cl.2.2.5.4 plus any additional<br />

<strong>in</strong>cremental width available.<br />

2.2.3.7 The capacity of means of escape <strong>in</strong> person per metre per<br />

m<strong>in</strong>ute (p/m/m<strong>in</strong>), passenger travel speeds <strong>in</strong> metres per<br />

m<strong>in</strong>ute (m/m<strong>in</strong>) shall be as follows:<br />

Type of means of<br />

escape<br />

Plat<strong>for</strong>ms, corridors and<br />

ramps not more than 4%<br />

<strong>in</strong> slope<br />

Stairs, escalators and<br />

ramps greater than 4%<br />

<strong>in</strong> slope<br />

Capacity<br />

(p/m/m<strong>in</strong>)<br />

80 (1) 60<br />

60 (2)<br />

Travel speed<br />

(m/m<strong>in</strong>)<br />

up 15 (3)<br />

down 18 (3)<br />

Doors and gates (5) 80 (4) N/A<br />

(1) In calculat<strong>in</strong>g the capacity of horizontal means of<br />

escape routes with a slope not exceed<strong>in</strong>g 4%,<br />

300mm shall be deducted at each sidewall and<br />

450mm at plat<strong>for</strong>m edges.<br />

(2) Refer to Cl.2.2.5.12 with respect to the allowable<br />

means of escape contribution <strong>for</strong> escalators.<br />

(3) The distance component of travel speed <strong>for</strong> stairs and<br />

stopped escalators is the vertical change <strong>in</strong> elevation.<br />

(4) Measurement of door width shall be <strong>in</strong> accordance<br />

with Cl.2.2.5.13(c).<br />

(5) Capacity <strong>for</strong> fare collection gates shall be <strong>in</strong><br />

accordance with Cl.2.2.3.8.<br />

2.2.3.8 Except as required by Cl. 2.2.3.9, the capacity <strong>for</strong> fare<br />

collection gates and turnstiles shall be as follows:<br />

Type of fare collection equipment Capacity<br />

Gates < 850mm wide 50 p/m<strong>in</strong> per gate<br />

Gates 850mm wide 80 p/m<strong>in</strong> per meter<br />

Turnstiles 25 p/m<strong>in</strong> per gate<br />

Determ<strong>in</strong>ation<br />

of exit<br />

capacity<br />

Capacity of<br />

means of<br />

escape<br />

<strong>Standard</strong> <strong>for</strong> <strong>Fire</strong> <strong>Safety</strong> <strong>in</strong> <strong>Rapid</strong> <strong>Transit</strong> <strong>Systems</strong> 21