SECTION 2.4<br />

SITE PLANNING & EXTERNAL<br />

FIRE FIGHTING PROVISIONS FOR STATIONS<br />

ROOT OBJECTIVES<br />

The primary <strong>in</strong>tentions of this section are encapsulated <strong>in</strong> the<br />

follow<strong>in</strong>g statements:-<br />

R2.4.1 Provide space at the station site to enable effective mount<strong>in</strong>g of<br />

fire-fight<strong>in</strong>g and rescue operations.<br />

R2.4.2 <strong>Fire</strong>-fighters must be provided with adequate means of access<br />

<strong>for</strong> fire-fight<strong>in</strong>g and rescue operations with<strong>in</strong> the station.<br />

R2.4.3 Provide reliable and adequate water supply to enable effective<br />

fire-fight<strong>in</strong>g operations.<br />

SUB-OBJECTIVES<br />

The follow<strong>in</strong>g criteria def<strong>in</strong>e the conditions necessary to fulfil<br />

the <strong>in</strong>tentions of this section:-<br />

S2.4.1 Provisions <strong>for</strong> adequate and appropriate access with proper<br />

identification <strong>for</strong> effective manoeuvr<strong>in</strong>g of fire-fight<strong>in</strong>g<br />

appliances at the station site <strong>for</strong> fire-fight<strong>in</strong>g purposes.<br />

S2.4.2 Provisions <strong>for</strong> adequate structural capacity of accessways with<br />

proper identification to support the operational loads of the<br />

fire-fight<strong>in</strong>g appliances.<br />

S2.4.3 Provisions <strong>for</strong> adequate and appropriate external entry<br />

locations with proper identification on the station facade <strong>for</strong><br />

fire-fight<strong>in</strong>g and rescue operations.<br />

S2.4.4 Provisions <strong>for</strong> adequate and appropriate access with proper<br />

identification <strong>in</strong>to underground station <strong>for</strong> fire-fight<strong>in</strong>g and<br />

rescue operations.<br />

S2.4.5 Provisions <strong>for</strong> appropriate sit<strong>in</strong>g of reliable and adequate<br />

hydrant water supplies and related facilities at the station site.<br />