Encased alum<strong>in</strong>ium alloy stanchions and beams<br />

(Mass per metre not less than 16 kg)<br />

A. SOLID PROTECTION *<br />

APPENDIX C - cont<strong>in</strong>ued<br />

PART VI : STRUCTURAL ALUMINIUM<br />

Construction and materials<br />

M<strong>in</strong>imum thickness<br />

(<strong>in</strong> mm) of protection<br />

<strong>for</strong> a fire resistance of<br />

4<br />

hours<br />

2<br />

hours<br />

1. Sprayed vermiculite-cement - - 44<br />

B. HOLLOW PROTECTION +<br />

1. Metal lath<strong>in</strong>g with vermiculite-gypsum or perlite-gypsum plaster of thickness of - 32 16<br />

2. Metal lath<strong>in</strong>g f<strong>in</strong>ished with neat gypsum plaster of thickness of - - 19<br />

3. Gypsum plasterboard 19 mm thick with 1.6 mm wire b<strong>in</strong>d<strong>in</strong>g at 100 mm pitch<br />

f<strong>in</strong>ished with gypsum-vermiculite plaster of thickness of<br />

* Solid protection means a cas<strong>in</strong>g which is bedded close to the alloy without <strong>in</strong>terven<strong>in</strong>g cavities and with all<br />

jo<strong>in</strong>ts <strong>in</strong> that cas<strong>in</strong>g made full and solid.<br />

+ Hollow protection means that there is a void between the protective material and the alloy. All hollow<br />

protection to columns shall be effectively sealed at each floor level.<br />

PART VII : REINFORCED CONCRETE FLOORS (DENSE CONCRETE)<br />

Description 4<br />

hours<br />

<strong>Standard</strong> <strong>for</strong> <strong>Fire</strong> <strong>Safety</strong> <strong>in</strong> <strong>Rapid</strong> <strong>Transit</strong> <strong>Systems</strong> C-9<br />

-<br />

22<br />

1<br />

hour<br />

10<br />

M<strong>in</strong>imum dimension<br />

to give fire resistance<br />

<strong>in</strong><br />

2<br />

hours<br />

1<br />

hour<br />

mm mm mm<br />

Solid floor slab, ribbed floor slab, hollow core slab to comply with SS CP 65 Part 2 - - -