2.2.5.8 BASEMENT EXIT STAIRCASE<br />
(a) Any exit staircase which serves a basement storey of<br />
a station shall comply with all the applicable<br />
provisions <strong>for</strong> exit staircase under Cl.2.2.5.6, and<br />
(b) Such exit staircase shall not be made cont<strong>in</strong>uous with<br />
any other exit staircase which serves a non-basement<br />
storey of the station, and<br />
(c) Basement exit staircases which are vertically aligned<br />
with the exit staircases of non-basement storeys shall<br />
be separated from such other exit staircases by<br />
construction hav<strong>in</strong>g fire resistance <strong>for</strong> a m<strong>in</strong>imum<br />
period equal to that required <strong>for</strong> the enclosure.<br />
2.2.5.9 SPIRAL STAIRCASE<br />
(a) Spiral staircases shall not serve as required exits<br />
except that external unenclosed spiral staircases when<br />
built of non-combustible materials and hav<strong>in</strong>g a tread<br />
length of at least 750mm may serve as required exits<br />
from mezzan<strong>in</strong>e floors and balconies or any storey<br />
hav<strong>in</strong>g an occupant load not exceed<strong>in</strong>g 25 persons,<br />
and<br />
2.2.5.10 EXIT RAMP<br />
(b) Such spiral staircases shall be not more than 10m<br />
high, and<br />
(c) Spiral staircases shall comply with the applicable<br />
requirements of Cl. 2.2.5.6.<br />
(a) Internal and external exit ramps may be used as exits<br />
<strong>in</strong> lieu of <strong>in</strong>ternal and external exit staircases subject<br />
to compliance to the applicable requirements of<br />
Cl.2.2.5.6, and<br />
(b) The m<strong>in</strong>imum width and capacity of exit ramp shall<br />
be <strong>in</strong> accordance with Cl. 2.2.3.7, Cl. 2.2.4.6 and<br />
Cl. 2.2.5.4.<br />
(c) The slope of such exit ramps shall not be steeper than<br />
1 <strong>in</strong> 12, and<br />
Basement exit<br />
staircase<br />
Spiral staircase<br />
Exit ramp<br />
<strong>Standard</strong> <strong>for</strong> <strong>Fire</strong> <strong>Safety</strong> <strong>in</strong> <strong>Rapid</strong> <strong>Transit</strong> <strong>Systems</strong> 31